Self-Contained Air Conditioning System 

Disposal

All conditioning units have a terminal strip, labeled 
for proper connections, inside the electric box. The 
wiring diagram inside the electric box supersedes ABYC 
standards. Use the correct size circuit breaker to protect 
the system as specified by the air conditioning units data 
plate label. A minimum of 12 AWG boat cable should 
be used to supply power to the air conditioning unit and 
the seawater pump. Make all connections using ring or 
captive fork terminals.

Observe the following when making electrical 
connections:

•  Alternating current (AC) grounding must be 

connected to the ground terminal (GRND) at the AC 
power input terminal block.

•  Connections between the vessel’s AC system 

grounding conductor and the vessel’s direct current 
(DC) negative or bonding system should be made 
as part of the vessel’s wiring. When servicing or 
replacing existing equipment that contains a chassis-
mounted ground stud, check the vessel’s wiring for 
these connections.

The air conditioning unit must be connected to the 
boat’s bonding system to prevent corrosion due to stray 
electrical current. Ensure that the AC ground of the 
air conditioning unit is properly connected to the AC 
ground of the boat. Within the boat itself, ensure that 
the AC ground bus is connected to the DC ground bus 
at exactly one place. All pumps, metallic valves, and 
fittings in the seawater circuit that are isolated from the 
air conditioning unit by PVC or rubber hoses, must be 
individually bonded to the boat’s bonding system.

7  Disposal

 

M

Place the packaging material in the appropriate 
recycling waste bins, whenever possible. Consult 
a local recycling center or specialist dealer for 
details about how to dispose of the product in 
accordance with all applicable national and local 
regulations.

8  Warranty Information

Refer to the sections below for information about 
warranty and warranty support in the US, Canada, and all 
other regions.

8 .1  United States and Canada

LIMITED WARRANTY AVAILABLE AT WWW.DOMETIC.
COM/WARRANTY.

IF YOU HAVE QUESTIONS, OR TO OBTAIN A COPY 
OF THE LIMITED WARRANTY FREE OF CHARGE, 
CONTACT:

DOMETIC CORPORATION 
MARINE CUSTOMER SUPPORT CENTER 
2000 NORTH ANDREWS AVENUE 
POMPANO BEACH, FLORIDA, USA 33069 
1-800-542-2477

8 .2 All Other Regions

The statutory warranty period applies. If the product is 
defective, please contact the manufacturer’s branch in 
your region (see the back of the instruction manual for 
the addresses) or your retailer.

For repair and guarantee processing, please include the 
following documents when you send in the device:

•  A copy of the receipt with purchasing date 

•  A reason for the claim or description of the fault

Summary of Contents for DCG

Page 1: ...ERS 339708 Form No L 4111 11 19 2019 Dometic Corporation WARNING Cancer and Reproductive Harm www P65Warnings ca gov DCG DCMG DCU DLM DLU DMT DTG DTU ECD MCS EN Self Contained Air Conditioning System Installation Manual 2 ...

Page 2: ...nstructions to help you eliminate or reduce the risk of accidents and injuries 1 1 Recognize Safety Information This is the safety alert symbol It is used to alert you to potential physical injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death 1 2 Understand Signal Words A signal word will identify safety messages and property damage messages and also wi...

Page 3: ...rvision This appliance should not be accessible to the general public Failure to follow these precautions could result in death or serious injury WARNING EXPLOSION HAZARD Do not install the air conditioning unit in a location containing gasoline engines tanks LPG CPG cylinders regulators valves or fuel line fittings Unless labeled otherwise self contained units do not meet federal requirements for...

Page 4: ...hoses electrical power connections location of the control and seawater pump placement to assure easy access for routing and future servicing See Figure 1 for an overview of the components in a typical self contained air conditioning system installation h j g f d s a o i u y t r e w q 1 Component Identification qSupply Air Grille and Transition Box oSeacock Shut Off Valve wDigital Display aSeawate...

Page 5: ...ameter in mm 3 0 76 4 0 102 5 0 127 6 0 152 6 0 152 7 0 178 7 0 178 8 0 203 Minimum Duct Area sq in sq cm 6 8 44 12 6 81 19 6 126 28 3 183 28 3 183 38 5 248 38 5 248 50 3 325 Minimum Return Air Grille sq in sq cm 64 0 413 64 0 413 80 0 516 100 0 645 130 0 839 200 0 1290 200 0 1290 240 0 1548 Minimum Supply Air Grille sq in sq cm 12 0 77 32 0 206 48 0 310 60 0 387 70 0 452 80 0 516 100 0 165 140 0 ...

Page 6: ...ning unit for installation 5 1 Determining the Installation Location 4 0 in 102 mm 3 0 in 76 mm 2 Placement Relating to Airflow qReturn Air Grille wBulkhead Allow for 3 0 in 76 mm minimum clearance in front of the evaporator coils and 4 0 in 102 mm minimum clearance in front of the return air grille 5 2 Rotating the Blower If needed rotate the blower to the direction that allows the most direct ai...

Page 7: ...ne particles from the cabin air and keep the evaporator coil clean Place one air filter either on the air conditioning unit or in the return air grille for each air conditioner unit Refer to General Information on page 4 for air filter placement 5 4 Placing the Grilles and Transition Boxes Install the supply air grille as high as possible in a location that will provide uniform air distribution th...

Page 8: ...tting 1 2 in HB x 12 MPT rDrain Pan wSolid Washer tLocking Nut eLiquid Seal Washer 1 Using the hose barb knock out a slug from an aft facing drain hole by applying one quick strike with a rubber mallet Discard the slug knockout 2 Install the hose barb For Turbo systems screw the hose barb into the threaded drain hole and tighten securely For all other systems thread the hose barb through a solid w...

Page 9: ...lation Insulate ducting when it is located in high heat areas Ensure that ducting is properly protected against damage when routed through open areas Do not route ducting through an engine room or any area where it may be exposed to dangerous vapors or exhaust fumes If a transition box is used the total area of supply air ducts going out of the box should be at least equal to the total area of the...

Page 10: ...ull flow seacock on the seawater scoop thru hull inlet 3 Install a seawater strainer below the level of the pump with access to the filter 4 Mount the pump above the strainer and at least one foot below the waterline 5 Connect the seacock and strainer with an uphill run of reinforced marine grade hose 6 Connect the discharge from the pump uphill to the bottom inlet of the air conditioning unit s c...

Page 11: ...oat Within the boat itself ensure that the AC ground bus is connected to the DC ground bus at exactly one place All pumps metallic valves and fittings in the seawater circuit that are isolated from the air conditioning unit by PVC or rubber hoses must be individually bonded to the boat s bonding system 7 Disposal M M Place the packaging material in the appropriate recycling waste bins whenever pos...

Page 12: ...com dealer YOUR LOCAL SUPPORT dometic com contact YOUR LOCAL SALES OFFICE dometic com sales offices A complete list of Dometic companies which comprise the Dometic Group can be found in the public filings of DOMETIC GROUP AB Hemvärnsgatan 15 SE 17154 Solna Sweden ...

Reviews: