EN
CRX50, CRX65
Technical data
27
Poor cooling, increase in interior temperature
Unusual noises
13
Technical data
Problem
Possible cause
Remedy
Compressor runs for a
long time/continuously
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Faulty fan
Replace the fan
Compressor does not
run often
Battery capacity exhausted
Charge the battery
Problem
Possible cause
Remedy
Loud humming
A component of the refrigerant circuit
cannot move freely (touching the
wall)
Bend the component
carefully away from the
obstruction
There is a foreign object stuck
between the cooling unit and the wall
Remove the foreign
object
Fan noise
Replace the fan
CRX50
CRX65
Model:
CRX0050
CRX0065
Refrigerator compartment storage
volume:
41.2 l
(1.45 cu.ft.)
50 l
(1.77 cu.ft.)
Freezer compartment storage
volume:
4.4 l
(0.16 cu.ft.)
7.0 l
(0.25 cu.ft.)
Total storage volume:
45 l
(1.59 cu.ft.)
57 l
(2.01 cu.ft.)
Voltage:
12 V
g
or 24 V
g