EN
Setting up and connecting the refrigerator
CRP40
16
A
For safety reasons the refrigerator is equipped with an electronic system to prevent
the polarity being reversed. This protects the refrigerator against reversed polarity
when connecting to a battery and against short circuiting. To protect the battery, the
refrigerator switches off automatically if the voltage is insufficient (see table below).
7.5
Connecting to a 230 V mains supply
D
➤
To operate the refrigerator on the 230 V mains, use the MPS-35 rectifier.
NOTICE!
Disconnect the device and other consumers from the battery before
charging the battery with a quick charging device.
Over voltages can damage the electronics of the device.
12 V
24 V
Cut-off voltage
10.4 V
22.8 V
Cut-in voltage
11.7 V
24.2 V
DANGER! Danger of fatal injuries!
•
Never handle plugs and switches with wet hands or if you are stand-
ing on a wet surface.
•
If you are operating your cooling device on board a boat with a mains
connection of 230 V from the land, you must install a residual current
circuit breaker between the 230 V mains supply and the cooling
device.
Get advice from a qualified specialist.