Before starting up the refrigerator for the first time, check whether the operating
voltage and the battery voltage match (see data plate).
➤
For the electrical connection you also need the wiring diagram (fig.
➤
Connect the refrigerator (fig.
–
as directly as possible to the poles of the battery or
–
to a plug socket which is fuse protected with at least 15 A (at 12 V) or 7.5 A
(at 24 V).
A
For safety reasons the refrigerator is equipped with an electronic system to prevent
the polarity being reversed. This protects the refrigerator against reversed polarity
when connecting to a battery and against short circuiting. To protect the battery, the
refrigerator switches off automatically if the voltage is insufficient (see table below).
Co-ordinate axis
Meaning
Unit
l
Cable length
m
Cable cross section
mm²
NOTICE!
Make sure that the polarity is correct.
Meaning
1
Electronic terminal rail
2
Compressor
3
DC fan (if present)
4
Mechanical thermostat
NOTICE!
Disconnect the refrigerator and other consumers from the battery
before charging the battery with a quick charging device.
Over voltages can damage the electronics of the refrigerator.
12 V
24 V
Cut-off voltage
10.4 V
22.8 V
Cut-in voltage
11.7 V
24.2 V
Summary of Contents for CoolMatic CRP 40S
Page 3: ...CRP40 3 380 545 182 53 310 200 132 536 23 1 2...
Page 4: ...CRP40 4 0 1 3 2 4 3 1 ca 50 mm 4...
Page 5: ...CRP40 5 5 1 Vent Lock 1 6...
Page 6: ...CRP40 6 8 7 mm l m 12V 24V 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 2 6 10 14 9...
Page 7: ...CRP40 7 bn bn bu bu 4 1 2 3 0 1 rd bk a...
Page 79: ......