EN
CF 18, CF 25, CF 35, CF 40, CF 50
Operation
19
A
In “HIGH” mode, the battery monitor responds faster than at the levels “LOW” and
“MED” (see the following table).
Selecting the battery monitor mode (CF 25, CF 35, CF 40, CF 50)
➤
Switch on the cooler.
➤
Press the “SET” button (fig.
4, page 4) three times.
➤
Use the “UP +” (fig.
6, page 4) and “DOWN –” (fig.
7, page 4) buttons to
select the battery monitor mode.
✓
The selected mode then appears in the display for a few seconds. The display
flashes several times before it returns to the current temperature.
I
NOTICE! Danger of damage!
When switched off by the battery monitor, the battery will no longer be
fully charged. Avoid continous starting and shutting off of the vehicles
engine when using the cooler in an automotive environment. Allow the
vehicle to recharge the battery before powering the cooler on.
CF 18
CF 25, CF 35, CF 40, CF 50
Battery monitor mode
LOW
HIGH
LOW
MED
HIGH
Switch-off voltage at 12 V
10.4 V
11.5 V
10.1 V
11.4 V
11.8 V
Restart voltage at 12 V
11.5 V
12.5 V
11.1 V
12.2 V
12.6 V
Switch-off voltage at 24 V
22.1 V
24.0 V
21.5 V
24.1 V
24.6 V
Restart voltage at 24 V
23.6 V
25.4 V
23.0 V
25.3 V
26.2 V
NOTE
When the cooler is supplied by the starter battery, select the battery
monitor mode “HIGH”. If the cooler is connected to a supply battery,
the battery monitor mode “LOW” will suffice.
If you wish to operate the cooler from the AC power supply, set the
battery monitor to the “LOW” position.