EN
Installation
Dometic Harrier Inverter
16
➤
Position the roof air conditioner over the installation opening.
There are markings on the roof plate to assist in locating the roof air conditioner
correctly. The base of the roof air conditioner should locate in the ribs of the roof
plate.
➤
Align centre indent lines on rooftop unit with 2 notches on the roof plate.
➤
Align bottom front edge of rooftop unit with 2 notches on the roof plate.
8.6
Making the mains electrical connection
D
➤
Locate the mains wiring and the communication cable which are tucked up in the
return air opening of the rooftop unit
➤
Gently pull them down into the RV.
➤
Make the mains connections using either the wiring quick connectors provided
or a suitable electrical junction box or terminals.
A
➤
Leave the communication cable free to be connected to the ADB transfer board
later in the installation process.
DANGER! Risk of electrocution
•
Make sure there is no voltage at electrically operated components
before carrying out work on them!
•
All electrical connections must be made by suitably qualified person
in accordance with local regulations.
NOTICE! Risk of damage
Ensure any excess electrical cables are secured where it cannot
interfere with or be damaged during the remaining installation or
from rubbing/vibration following installation.
1
2
1.
2.
3.
b
54-AA-MA53501.book Seite 16 Dienstag, 19. Februar 2019 2:20 14