- 5 -

VENTILATION REQUIREMENTS

OVERALL AND RECESS DIMENSIONS

   

               Dimensions

               Dimensions

Model

Overall 

Recess

Height A

Width B

Depth C

Height H

Width W

Depth D

RM2351

RM2354

inches

30-5/32

21-7/8

22-22/32

29-3/4

20-1/2

21-3/8

mm

766

556

577

756

521

542

RM2451

RM2454

inches

37-3/8

24-7/8

24-11/16

39-9/16

23-11/16

24

mm

948

632

627

928

602

610

RM2551

RM2554

inches

43-1/2

24-7/8

24-11/16

42-5/8

23-11/16

24

mm

1104

632

627

1083

602

610

RM2652

RM2662

RM2663

inches

54-21/32

24-7/8

26-1/32

53-3/4

23-11/16

24

mm

1388

632

661

1365

602

610

RM2852

RM2862

RM3862

inches

60-51/64

24-7/8

26-1/32

59-15/16

23-11/16

24

mm

1544

632

661

1522

602

610

NDR1062

inches

60-54/64

24-7/8

26-5/8

59-15/16

23-11/16

24

mm

1544

632

676

1522

602

610

Side view

View from above

General view. Features may vary according to model. 

Summary of Contents for AMERICANA RM2652

Page 1: ... toute flamme nue 4 Avertissez immédiatement votre fournisseur de gaz FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance POUR VOTRE SÉCURITÉ Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflamma bles à proximité de cet appareil ou de tout autre appareil Improper installation adjustment altera ...

Page 2: ...le safety hazards when seeing alert symbols on the refrigerator as well as in this manual Modifica tion of this product can be hazardous and could result in personal injury or property damage INTRODUCTION CONTENTS CONTENTS CERTIFICATION AND CODE REQUIREMENTS______ 3 VENTILATION REQUIREMENTS__________________ 3 General information 3 Venti Venti V lation heights 4 Clearances 4 Overall and recess dime...

Page 3: ...5 751 RM123A 3109492 003 RM183 3109492 003 RM2451 RM2454 RM2551 RM2554 3A Roof Base Roof Cover Lower Side Vent 3103633 XXX 3103634 XXX 3109350 XXX RM2652 RM2662 RM2663 RM2852 RM2862 RM3862 NDR1062 4A Roof Base Roof Cover Lower Side Vent 3103633 XXX 3103634 XXX 3109350 XXX GENERAL INFORMATION Ventilation is one of the requirements for proper cooling unit operation The installation should be made in...

Page 4: ...ndent on adequate flow of air over the rear of the refrigerator Minimum ventilation heights Roof vent and lower side vent Upper and lower side vent RM2351 RM2354 inches mm inches mm 31 787 34 864 RM2451 RM2454 37 3 4 960 RM2551 RM2554 44 1 2 1130 RM2652 RM2662 RM2663 57 3 4 1465 RM2852 RM2862 RM3862 NDR1062 63 3 4 1620 A B B Minimum ventilation height Condenser Condenser Condenser Condenser Condens...

Page 5: ... 23 11 16 24 mm 948 632 627 928 602 610 RM2551 RM2554 inches 43 1 2 24 7 8 24 11 16 42 5 8 23 11 16 24 mm 1104 632 627 1083 602 610 RM2652 RM2662 RM2663 inches 54 21 32 24 7 8 26 1 32 53 3 4 23 11 16 24 mm 1388 632 661 1365 602 610 RM2852 RM2862 RM3862 inches 60 51 64 24 7 8 26 1 32 59 15 16 23 11 16 24 mm 1544 632 661 1522 602 610 NDR1062 inches 60 54 64 24 7 8 26 5 8 59 15 16 23 11 16 24 mm 1544...

Page 6: ...l not to damage the sealing strip when the refrigerator is put in place SECURING THE REFRIGERATOR When installing the refrigerator make sure the heat can not be trapped in the space between the refrigerator and storage area This would make the top of the refrigerator hot and reduces the efficiency of the refrigerator Any space between the counter storage area or ceiling and top of the refrigerator ...

Page 7: ... the drilled hole If a longer hose than supplied is required to get the water to drain outside of the vehicle the installer will have to supply the extra length of hose CONNECTIONS Gas connection Hook up to the gas supply line is accomplished at the manual gas valve which is furnished with a 3 8 SAE UNF 5 8 18 male flare connection All completed connections should be ex amined for leaks using a sol...

Page 8: ...k on Normal operation of the burner should return Allow the burner to operate for a minimum of five minutes RM2351 2451 2551 2652 2852 To test the gas safety shut off follow these steps Start the refrigerator without connecting to 120 V AC Check that the gas flame is lit In AUTO mode the AUTO mode indicator lamp is on Then follow steps 3 11 in instruction above 1 2 3 4 5 6 7 8 9 10 11 1 2 3 Electric...

Page 9: ...10 8 17 27 5 8 For 3 way models the voltage drop affects the wattage output of the 12V cartridge heater and the refrigerator performance The 12V DC heater is fused with a 30 amp in line blade fuse Recommended wire sizes are displayed in the following table REVERSING THE DOOR SWING The refrigerator is equipped with hinges that makes it possible to change the direction the door opens by moving the h...

Page 10: ...nt the panel follow these steps Open the door 90 de grees On new refrigerators the decoration strip is taped inside the door if installed on the door re move the door decoration strip 2 by removing its three screws 1 Insert the vertical edges into the grooves of the door frame 3 Push the panel down wards so that the lower horizontal edge of the panel 4 is fitted into the bottom grove 5 Put the deco...

Page 11: ...tting Manual gas shutoff valve Burner jet Screw for protection cover Protection cover Drain water hose Flue baffle Heater Power module cover Flexible cord 12 V DC Terminal block Inlet fitting Manual gas shutoff valve Burner jet Screw for protection cover Protection cover Drain water hose Flue baffle Heaters Relay ...

Page 12: ...f valve Burner jet Screw for protection cover Protection cover Flue baffle Heater s Thermofuse Flexible cord Power module cover Relay 3 way only 12 volt Terminal block Drain water hose Inlet fitting Manual gas shutoff valve Burner jet Screw for protection cover Heater Flue baffle Protection cover 12V DC RM2451 2454 2551 2554 RM2652 2662 2663 2852 2862 3862 NDR1062 ...

Page 13: ... 13 APPENDIX B WIRING DIAGRAMS RM2351 2451 2551 RM2354 2454 2554 ...

Page 14: ... 14 APPENDIX B WIRING DIAGRAMS RM2652 2662 2852 2862 RM2663 ...

Page 15: ... 15 APPENDIX B WIRING DIAGRAMS RM3862 NDR1062 BS SS BS Black stainless steel doors SS Stainless steel doors B Door insert panels NDR1062 B ...

Page 16: ...TO THE INSTALLER PLEASE AFFIX THESE INSTRUCTIONS TO THE REFRIGERATOR TO THE CONSUMER PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE ...