EN
Harrier series
Technical data
27
•
manufacturing, installing, commissioning, servicing or maintaining equipment
regardless of whether it is charged with refrigerant or not
•
decommissioning or disposing of equipment where refrigerant is present
Discharge of refrigerant into the atmosphere is against the law. Severe penalties
apply.
13
Technical data
Contains fluorinated greenhouse gases. Hermetically sealed equipment.
Harrier Lite
HL36H401RI,
HL36H401RIY
Harrier Plus
HP36H401RI,
HP36H401RIY
Compressor cooling capacity:
3600 W
Cooling capacity based on ISO 5151:
2413 W
3028 W
Heating capacity based on ISO 5151:
2421 W
3017 W
Rated input voltage:
220 to 240 V
w
/ 50 – 60 Hz
Rated current cooling:
7.5 A
6.9 A
Rated current heating
6.1 A
5.9 A
Required fuse:
10 A
Operating temperature range:
–2 °C to +52 °C
Refrigerant:
R-410A
Refrigerant quantity:
0.650 kg
0.750 kg
CO
2
equivalent:
1.357 t
1.566 t
Global warming potential (GWP):
2088
Protection class (outdoor unit):
IPX4
Suggested max. vehicle length
(with insulated walls):
<6 m
>7.5 m
Dimensions L x W x H
(height above vehicle roof):
997 x 665 x 240 mm
1070 x 750 x 280 mm
Weight:
37 kg
44 kg
Inspection/certification: