EN
RTX1000/2000, SPX1200
Using the parking cooler
15
I
7.4
Switching off the parking cooler
➤
Press the
button for at least 3 s to switch off parking cooler.
✔
The parking cooler saves the current settings.
✔
The
Power
LED (fig.
I
7.5
Using menus
You can set the parking cooler to suit your requirements using the menus:
1. Press the
button to browse through the menus.
2. Press the
or
button to navigate to the appropriate sub-menu or to
change the selected value.
3. Press the
button to
reduce
the selected value.
4. Press the
button to
increase
the selected value.
I
NOTE
•
When the parking cooler is in BOOST mode and switched to
standby mode, it will start the next time in AUTO mode.
•
A running timer is set to 0 by switching the parking cooler in standby
mode.
•
The parking cooler switches off completely after 12 hours in standby
mode to save power.
•
SPX1200T, SPX 1200C only:
When the parking cooler is switched
to standby mode via remote control, an automatic pump cycle of 8 s
is started.
NOTE
•
When the parking cooler is in BOOST mode and switched off, it will
start the next time in AUTO mode.
•
A running timer is set to 0 by switching off the parking cooler.
•
If the parking cooler is switched off while the compressor is still
operating, the fan will continue to run for 20 s to dry the evaporator,
among other things.
•
SPX1200T, SPX 1200C only:
When the parking cooler is switched
off, an automatic pump cycle of 8 s is started.
NOTE
If you don‘t press any button for more than 5 s, the display switches back
to the menu mode.
DometicRTX1000-RTX2000-SPX1200_OPM_4445101929_EMEA17_202x-xx-xx.book Seite 15 Donnerstag, 21. Oktober 2021 10:06 22