7
OPERATION
F. Closing The Awning Using An Auxiliary Power Method
ELECTRICAL SHOCK HAZARD. Disconnect power from product before accessing wiring connections. There may be issues
mimicking a power failure with electric current still present, or power may return unexpectedly. Failure to obey this warning could result in
death or serious injury.
Rule out simple causes for power failure BEFORE proceeding. Refer to “Troubleshooting” on page 14. After awning is closed manu-
ally, it will require service by a qualified service technician.
STEP 1
Receiver
Wiring
RH End Cap
• Disconnect power to the RV, the receiver unit, and the awning.
• Unplug the motor connector from the RV wiring connector
inside the RH end cap.
• Using 16 gauge wire leads, connect the positive (+) lead wire
to the BLUE motor wire and the negative (–) lead wire to the
BROWN motor wire. Secure using electrical tape.
• Connect the other end of the wire leads to the
positive (+) and negative (–) terminals on an external
12 VDC power source.
• Disconnect the wire leads from the power source when the
awning retracts fully.
If the awning does not retract, proceed to “G. Closing The
Awning Manually” on page 8.