Troubleshooting
35
Compressor is not running (connected to AC supply)
Poor cooling, increase in interior temperature
U
Term
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics
Problem
Possible cause
Remedy
No voltage
Connection supply line interrupted
Establish a connection
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
Voltage is present but
the compressor doesn't
run
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor
Contact customer service
Problem
Possible cause
Remedy
Compressor runs for a
long time/continuously
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Faulty fan
Replace the fan
Compressor does not
run often
Battery capacity exhausted
Charge the battery
CRX50-65-80-110-140-IO-US.book Seite 35 Mittwoch, 15. Juli 2020 10:16 10
Summary of Contents for 9105305962
Page 8: ...CRX 8 2 1 9 1 2 0 CRX50 65 80 110 140 IO US book Seite 8 Mittwoch 15 Juli 2020 10 16 10 ...
Page 9: ...CRX 9 a b c CRX50 65 80 110 140 IO US book Seite 9 Mittwoch 15 Juli 2020 10 16 10 ...
Page 11: ...CRX 11 1 rd bk f 1 2 g CRX50 65 80 110 140 IO US book Seite 11 Mittwoch 15 Juli 2020 10 16 10 ...
Page 91: ...CRX50 65 80 110 140 IO US book Seite 91 Mittwoch 15 Juli 2020 10 16 10 ...