![Dometic 9105305764 Installation Manual Download Page 8](http://html1.mh-extra.com/html/dometic/9105305764/9105305764_installation-manual_2518174008.webp)
Installation
FW 3000
EN
8
Note on electrical system (see fig.
)
•
Only a qualified electrician should connect the under-bench air conditioner to the electrical power.
•
Check that the voltage specification on the type plate is the same as that of the power supply.
•
Do not lay cables which are loose or bent next to electrically conductive material (metal).
•
Install an all-pole switch with a contact opening width of at least 3 mm on the installation side.
•
If the appliance is powered by the mains, install a 2-pole switch that interrupts the AC voltage supply in case of
over current.
•
If the appliance is powered by the mains, ensure that the AC voltage supply has a residual current circuit
breaker.
•
Make sure that the grounding cable of the air conditioner is connected to the vehicle‘s grounding system.
7.2 Making openings
See fig.
➤
Mark the position and size of the openings using the template included in the packaging (
A
and
B
).
See fig.
➤
Drill out the corners (
A
).
➤
Carefully cut out the openings using a keyhole saw or a similar tool (
B
).
Make sure no electrical power cables are damaged.
➤
Drill out a condensation water drainage opening with a diameter of 32 mm (
C
).
See fig.
➤
Mark the position of the angle sections (
A
) and the fastening brackets (
B
).
7.3 Installing the fastening brackets and belts
See fig.
➤
Fasten the four fastening brackets (
A
).
➤
Pull the belts through the fastening brackets (
B
).
➤
Install the drain pipes under the under-bench air conditioner (
C
).
No. in fig.
Description
1
Motor ventilator (inner)
2
Motor ventilator (outer)
3
Capacitor
4
Compressor
5
Temperature sensor
6
PCB
7
PCB display
8
PCB interface
9
Soft start
10
Valve
11
Resistor
DometicFreshWell3000_INM_4445101819_EMEA16_xxxx-xx-xx.book Page 8 Thursday, January 19, 2023 12:51 PM