10
Dometic 8700 Series MasterFlush Toilet
Installation
5.4
Toilet system with flush handle and through-the-floor connections
- all applications
1 . Follow steps 1-3 in Section 5 .3 .
2 . Plan electronic control module and status panel locations so that electrical connections can be
made with cables provided . Be sure module and wires cannot get wet .
3 . Use Dometic wall switch template to mark location of fastener and access holes for DSS status
panel (fig .
1
N
, p . 2) . Drill wiring access hole, then fasten panel bracket to wall .
4 . Route flush handle cable (fig .
1
O
, p . 2) from flush handle cable on control module (fig .
1
F
,
p . 2) to toilet location, and route ethernet cable (fig .
1
E
, p . 2) to DSS status panel location .
(If using status panel other than Dometic DSS panel, route orange connector end of Dometic
flush handle cable (fig .
1
O
, p . 2) through access hole at toilet location . Route other section of
cable through status panel access hole and connect to panel wires . Attach status panel to wall .)
5 . Install control module in cool, dry location, then attach Dometic flush switch/status panel cable(s)
to control module (fig .
18
) .
6 . With electrical power off, complete wiring connections to control module . Refer to wiring diagram
printed with parts list (packed separately) .
7 . Route 4-wire control module cable (fig .
1
D
, p . 2) to toilet through access hole .
8 . Route water supply and discharge plumbing to toilet according to system requirements (
Section
4.2
) . Make sure to provide extra discharge hose length to assure easy connection to toilet
(fig .
19
) .
9 . Follow steps 11-13 in Section 5 .3 to connect discharge plumbing and 4-pin connector at toilet .
10 . Connect 3-pin flush handle cable connector to 3-pin wire from control module (fig .
20
) .
11 . Follow steps 14-17 from Section 5 .3 to finish installation and testing . Press flush handle down
when testing operation and checking connections .
18
20
19