A. Table - Unit Data
Model No.
Nominal
Capacity
(BTU HR)
Cooling
Electrical
Rating
120 Vac
60 Hz 1 ph
Compressor
Rated Load
Amps
Compressor
Locked
Rotor
Amps
Fan Motor
Rated Load
Amps
Fan Motor
Locked
Rotor
Amps
Refrigerant
R-410A
(oz)
Minimum
Wire Size*
12 AWG
Copper
Up to 24'
AC Circuit
Protection
***Installer
Supplied
Minimum
Generator
Size**
1 Unit / 2 Units
640312.30X
11,000
10.5
53.0
3.5
10.0
19.0
20 Amp
3.5 kW / 5.0 kW
640312C35X
11,000
10.5
53.0
3.5
10.0
19.0
20 Amp
3.5 kW / 5.0 kW
640312.80X
11,000
11.5
53.0
2.6
8.5
20.0
20 Amp
3.5 kW / 5.0 kW
640312.83X
11,000
12.5
63.0
2.6
8.5
18.0
20 Amp
3.5 kW / 5.0 kW
640312C85X
11,000
11.5
53.0
2.6
8.5
20.0
20 Amp
3.5 kW / 5.0 kW
640315.30X
13,500
12.5
61.0
3.5
10.0
17.5
20 Amp
3.5 kW / 5.0 kW
640315C35X
13,500
12.5
61.0
3.5
10.0
17.5
20 Amp
3.5 kW / 5.0 kW
640315.80X
13,500
12.6
63.0
2.6
8.5
18.0
20 Amp
3.5 kW / 5.0 kW
640315.83X
13,500
12.5
63.0
2.6
8.5
19.0
20 Amp
3.5 kW / 5.0 kW
640315.84X
13,500
12.5
63.0
3.5
8.5
19.0
20 Amp
3.5 kW / 5.0 kW
640315C85X
13,500
12.6
63.0
2.6
8.5
18.0
20 Amp
3.5 kW / 5.0 kW
* For wire length over 24 ft., consult the National Electrical Code for proper sizing.
** Dometic Corporation gives
GENERAL
guidelines for generator requirements. These guidelines come from experiences
people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B. Roof Requirements
● A 14-1/4″ x 14-1/4″ (±1/8″) square opening (hereinafter referred to as “roof opening”) is required for installing this
unit. This opening is part of the return air system of the unit and
MUST
be finished in accordance with NFPA 1192.
●
Roof construction with rafters/joists support frames on a minimum of 16 inch centers.
●
Minimum of 2 inches and maximum of 5-1/2 inches distance between roof to ceiling of RV.
C. Table - Air Distribution Duct Sizing & Design
Return Air Grille Kit
3105007.XXX
3105935.XXX
Roof Cavity Depth
2.0 In. Min. - 5-1/2 In. Max.
Duct Cross Sectional Area
21.0 Sq. In. Min.
*Duct Size
Depth
Width
Total Duct Length
Duct Length (short run)
1-1/2 In. Min. - 2-1/2 In. Max.
7.0 In. Min. - 10.0 In. Max.
15.0 Ft. Min. - 40.0 Ft. Max.
1/3 Total Duct Length
Register Requirements per A/C Unit
Number Required
Register Free Air Area
Distance From Duct End
Distance From Elbow
4 Min. - 8 Max.
14.0 Sq. In.
5.0 In. Min. - 8.0 In. Max.
15.0 In.
Total System Static Air Pressure
Blower at High Speed,
Filter & Grill In Place
0.12 - 0.65 In W.C.
*
Duct sizes listed are inside dimensions. Duct material
MUST
meet or exceed any agency or RVIA Standard in effect at the
time the RV is manufactured.
SPECIFICATIONS