Dometic 620412.331 Installation Instructions Manual Download Page 5

5

FIG. 5

FIG. 6

Do Not Cut
Roof Structure
Or Rafters

Good-Rafters
Supported By
Cross Beams

Good Location-
Between Roof
Rafters

Frame Opening So It
Won't Collapse When
Bolting Down Unit

Leave Access For Power
Supply Wiring

15" Min. At
Front Of
Opening

3/4" Min.

It is the responsibility of the installer of this
air conditioner system to ensure structural
integrity of the RV roof. Never create a low
spot on the roof where water will collect. Wa-
ter standing around the air conditioner may
leak into the interior causing damage to the
product and the RV.

CAUTION

620412, 620415, 620425 & 620426 Series Installation Instructions

C. Roof Preparation

1.

Opening Requirements - Before preparing the ceil-
ing opening, the type of system options must be
decided upon. Read all of the following instructions
before beginning the installation.
If a roof vent opening will not be used a 14-1/4" x 14-
1/4" (±1/8") opening must be cut through the roof and
ceiling of the RV. This opening must be located
between the roof reinforcing members.

The 14-1/4" x 14-1/4" (±1/8") opening is part of the
return air system of the Air Conditioner and must be
finished in accordance with NFPA Standard 501C
Section 2.7.2.

2.

Roof Vent Removal

a.

Unscrew and remove the roof vent.

b.

Remove all caulking compound around open-
ing.

c.

Seal all screw holes and seams where the roof
gasket is located. Use a good grade of all
weather sealant. See FIG. 5.

d.

If the opening exceeds 14-3/8" x 14-3/8", it will
be necessary to re-size the opening to 14-1/4"
x 14-1/4" (±1/8").

e.

If the opening is less than 14-1/8" x 14-1/8", it
must be enlarged.

3. New Opening- (Installation Other Than Vent Open-

ing)
a.

Mark a 14-1/4" x 14-1/4" (±1/8") square on the
roof and carefully cut the opening.

b.

Using the roof opening as a guide, cut the
matching hole in the ceiling.

c.

The opening created must be framed to provide
adequate support and prevent air from being
drawn from the roof cavity. Lumber 3/4" or more
in thickness must be used. Remember to pro-
vide an entrance hole for power supplies, fur-
nace wiring and a seven-conductor cable, 18 to
22 AWG is to be used for analog thermostat
connections.

There may be electrical wiring between the
roof and the ceiling. Disconnect 120 volt AC
power cord and the positive (+) 12 volt DC  ter-
minal at the supply battery. Failure to follow
this instruction may create a shock hazard
causing death or severe personal injury.

FIG. 4

14-1/4" x 14-1/4”

(±1/8”) OPENING

21-3/8”

KEEP THESE AREAS
FREE OF OBSTRUCTIONS

12"

REAR
OF
UNIT

4"

4"

4-1/8”

7-1/8”

7-1/8”

Center Line
of Unit

1-1/4"

1-1/2"

1-3/4"

1-1/2"

17"

17"

20-7/8"

3"

2"

2"

18-1/2"

3"

Air Grill Perimeter

14-1/4 x 14-1/4
(±1/8")
Opening

Genesis

R

e

a

r

F

r

o

n

t

Standard
Grill

14-1/4 x 14-1/4
(±1/8")
Opening

Summary of Contents for 620412.331

Page 1: ...ld result in personal injury or property damage Lire et comprendre ce manuel avant de proc der l installation desr glages de l entretien ou des r parations L installation de cet appareil doit tre effe...

Page 2: ...than 5 50 inches thick C The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the RV Somepreventativemeasurestakenbytheoccupantsofthe RVcanreducet...

Page 3: ...length over 24 ft consult the National Electric Code for proper sizing Dometic Corporation gives GENERAL guidelines for generator requirements These guidelines come from experiences people have had in...

Page 4: ...ions 2 Other Locations When no roof vent is available or another location is desired the following is recom mended a For one unit installation The air conditioner should be mounted slightly forward of...

Page 5: ...compound around open ing c Seal all screw holes and seams where the roof gasket is located Use a good grade of all weather sealant See FIG 5 d If the opening exceeds 14 3 8 x 14 3 8 it will be necess...

Page 6: ...GN CHART 620412 620415 620425 620426 Series Installation Instructions 4 Air Distribution System Sizing Design The Installer of this air conditioner system must designtheairdistributionsystemfortheirpa...

Page 7: ...gisters 4 Min 8 Max Per Unit 14 Sq In Free Area Per Register FRAME 14 1 4 1 8 OPENING AC POWER SUPPLY WIRE DUCT FRAME DUCT ROOF INSULATION DUCT CEILING DUCT 14 1 4 1 8 OPENING INSULATION SIDE VIEW TOW...

Page 8: ...rect heat from lamps sun or other heat producing items d Avoid locations close to doors that lead out side windows or adjoining outside walls e Avoid locations close to supply registers and the air fr...

Page 9: ...he RV See FIG 9 Thiscompletestheoutsidework Minoradjustments can be done from the inside of the RV if required G Installing The Air Conditioner Installing Unit with 3105007 or 3105935 Return Air Kit F...

Page 10: ...bolts are self locking so over tightening is not necessary See FIG 14 2 Installation of Divider Plate a Measure the ceiling to roof thickness If distance is 2 0 3 3 4 remove perfo rated tab from divid...

Page 11: ...1 Center Discharge DuctAppli cation Installation on page 12 a Check gasket alignment of the air conditioner over the roof opening and adjust if necessary Unit may be moved from below by slightly lift...

Page 12: ...filter from the 3308120 carton Locate the four 8 x 1 4 20 unit mounting bolts junction box cover and Romex con nector in the 3107180 bolt kit Pull down the unit s electrical cord and fas ten the junct...

Page 13: ...onnect the orange wire protruding from the units return air opening to the seven wire cable connected at thermostat HS HP terminal if applicable i Connectthewhitewireprotrudingfromtheunits return air...

Page 14: ...d it in place Connect to gether the wires from the thermostat unit and filter indicator Note If solar panel is installed see instructions packaged with solar panel option a Connect the red wire from t...

Page 15: ...O 115 VAC 60 Hz 1O TO 115 VAC 60 Hz 1O TO LOW VOLT THERMOSTAT CABLE TO LOW VOLT THERMOSTAT CABLE BLU WHT BLU WHT HEAT ACCESSORY WHT BLK BLK ELEMENT LIMIT 3 1 SWITCH WHT BLK OL FUSE SPLICE CAP SPLICE C...