A. Table - Unit Data
Model No.
Nominal
Capacity
(BTU HR)
Cooling
Electrical
Rating
120 Vac
60 Hz 1 ph
Compressor
Rated Load
Amps
Compressor
Locked
Rotor
Amps
Fan Motor
Rated Load
Amps
Fan Motor
Locked
Rotor
Amps
Refrigerant
R-410A
(oz)
Minimum
Wire Size*
12 AWG
Copper
Up to 24'
AC Circuit
Protection
***Installer
Supplied
Minimum
Generator
Size**
1 Unit / 2 Units
459146.70X
15,000
13.3
66.0
2.0
5.6
29.0
20 Amp
3.5 kW / 5.0 kW
459146.71X
15,000
13.3
70.0
2.0
5.6
29.0
20 Amp
3.5 kW / 5.0 kW
B59146.71X
15,000
13.3
70.0
2.0
5.6
29.0
20 Amp
3.5 kW / 5.0 kW
* For wire length over 24 ft., consult the National Electrical Code for proper sizing.
** Dometic Corporation gives
GENERAL
guidelines for generator requirements. These guidelines come from experiences
people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B. Roof Requirements
● A 14-1/4″ x 14-1/4″ (±1/8″) square opening (hereinafter referred to as “roof opening”) is required for installing this
unit. This opening is part of the return air system of the unit and
MUST
be finished in accordance with NFPA 1192.
●
Roof construction with rafters/joists support frames on a minimum of 16 inch centers.
●
Minimum of 1.5 inches and maximum of 6 inches distance between roof to ceiling of RV.
SPECIFICATIONS