![Dometic 3341P Installation & Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/dometic/3341p/3341p_installation-and-operating-instructions-manual_2518143006.webp)
6
FIG. 4
Lift And Place
Front Towards Bow
Do Not Slide
Rear
Front
4. Place the ADB kit (ordered separately) inside
the boat. This box contains mounting hardware
for the unit and will be used inside the boat.
This completes the outside work. Minor
adjustments can be done from inside the
boat if required.
E. Installing Unit
1.
Check for correct alignment and adjust the unit
as necessary (roof gasket centers over the roof
opening). See (FIG. 5).
FIG. 5
Center Unit From Below
Roof Gasket
2. Remove ADB and mounting hardware from car-
ton. See (FIG. 6).
19 mm Min.
Leave Access For
Power Supply Wiring
FIG. 3
381 mm Min.
At Front Of
Opening
Do Not Cut Roof
Structure Or
Rafters
Good-Rafters
Supported By
Cross Beams
Good Location
Between Roof
Rafters
Frame Opening So It
Won't Collapse When
Bolting Down Unit
C. Wiring Requirements
1. Route a copper, with ground, 220 - 240 Vac sup-
ply wire from the time delay fuse or circuit break-
er box to the roof opening. Use a listed/certified
non metallic - sheathed single strand cable. See
“A. Table - Unit Data” on page (4).
a. This supply wire must be located in the front
portion of the roof opening.
b. The power
MUST
be on an appropriately
sized separate time delay fuse or circuit
breaker. See “A. Table - Unit Data” on page
(4).
c. Make sure that at least 381 mm of supply
wire extends into the roof opening. This in-
sures an easy connection at the junction box.
d. Protect the wire where it passes into the
opening with approved method.
D. Placing Unit On Roof
1. Remove the unit from the carton and discard
carton.
2.
LIFTING HAZARD. Use proper
lifting technique and control when lifting product.
Failure to obey this caution could result in injury.
Place unit on the roof.
3.
Do
NOT
slide unit. Otherwise,
damage to gasket (on bottom of unit) may occur,
and could cause a leak.
Lift and place the unit over the prepared open-
ing using the gasket on the unit as a guide. See
(FIG. 4).
INSTALLATION INSTRUCTIONS