25

CAUTION

C. Roof Preparation

1.

Opening Requirements - Before preparing the ceil-
ing opening, read all of the following instructions
before beginning the installation.
If an existing roof vent opening will not be used a
362mm x 362mm (± 3.2mm) opening must be cut
through the roof and ceiling of the Caravan. This
opening must be located between the roof reinforc-
ing members.

There may be electrical wiring between the
roof and the ceiling. Disconnect 220 - 240 Volt
AC power cord and the positive (+) 12 Volt DC
terminal at the supply battery. Failure to fol-
low this instruction may create a shock haz-
ard causing death or severe personal injury.

FIG. 5

The 362mm x 362mm (± 3.2mm) opening is part of
the return air system of the Air Conditioner and must
be finished in accordance with all Nation and local
codes and/or regulations.

2.

Roof Vent Removal
a.

Unscrew and remove the roof vent.

b.

Remove all caulking compound around open-
ing.

c.

Seal all screw holes and seams where the roof
gasket is located. Use a good grade of all
weather sealant. See FIG. 6.

9-1/2"

39"

28-3/4"

20"

2-1/2"

22"

FIG. 4

24cm

102cm

74cm

51cm

6.4cm

56cm

510mm

283
mm

105
mm

105
mm

283
mm

75mm

75mm

Center Line
Of Opening

Air Box
Perimeter

Keep This Area
Free From
Obstructions

105mm

181mm

181mm

362mm x
362mm
(± 3.2mm)
Opening

543mm

Center Line Of Unit

305mm

102mm

102mm

Rear
O f
Unit

362mm x
362mm
(± 3.2mm)
Opening

3.

After Location Has Been Selected:
a.

Check for obstructions in the area where air
conditioner will be installed. See FIG. 4.

b.

The roof must be designed to support 65 Kg.
when the Caravan is in motion. Normally
a 100Kg. static load design will meet this
requirement.

It is the responsibility of the installer of this
air conditioner system to ensure structural in-
tegrity of the Caravan roof. Never create a low
spot on the roof where water will collect. Wa-
ter standing around the air conditioner may
leak into the interior causing damage to the
product and the Caravan.

c.

Check inside the Caravan for return air kit
obstructions (i.e. door openings, room dividers,
curtains, ceiling fixtures, etc.). See FIG. 4 & 5.

Summary of Contents for 3253.331

Page 1: ...tion of this product can be extremely haz ardous and could result in personal injury or property damage Roof Top Air Conditioner CARAVAN MODEL B3200 TYPE 3253 331 Model B3200 SERVICE OFFICE DometicCorporation ForInformation Contact www dometic com Form No 3310147 000 Danish Dutch English Finnish French German Greek Italian Norwegian Portuguese Spanish Swedish 2005 5 05 Dometic GmbH D 57074 Siegen ...

Page 2: ...ow for roofs more than 100mm thick C The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the Caravan Somepreventativemeasurestakenbytheoccupantsof the Caravan can reduce the heat gain and improve the performance of the air conditioner During extremely highoutdoortemperatures theheatgainoftheCaravan may be reduced by 1 Parking the Caravan in a s...

Page 3: ...331 NominalCompressor Capacity KW 3 2 1 5 ElectricalRating 220 240 VAC 50Hz 1 Ph Full Load Amps Compressor Motor 5 2 0 8 6 0 0 8 LockedRotorAmps Comp Motor 24 5 0 6 0 5 0 CircuitProtection 10 Amp Time Delay Fuse or Circuit Breaker Input Power KW 1 35 1 64 Minimum Wire Size Up to 8 meters use 1mm2 Copper Generator Size 1 Unit 3 5KW 2 Units 5 0KW Improper installation may damage equipment could enda...

Page 4: ...rew holes and seams where the roof gasket is located Use a good grade of all weather sealant See FIG 6 9 1 2 39 28 3 4 20 2 1 2 22 FIG 4 24cm 102cm 74cm 51cm 6 4cm 56cm 510mm 283 mm 105 mm 105 mm 283 mm 75mm 75mm Center Line Of Opening Air Box Perimeter Keep This Area Free From Obstructions 105mm 181mm 181mm 362mmx 362mm 3 2mm Opening 543mm Center Line Of Unit 305mm 102mm 102mm Rear Of Unit 362mm ...

Page 5: ...ct Water standing around the air conditioner may leak into the interior causing damage to the product and the Caravan CAUTION D Wiring Requirements 1 220 240 VAC Supply Line Route a copper 1mm2 with ground 220 240 VAC supply line from the time delay fuse or circuit breaker box to the roof opening a This supply line must be located in the front portion of the 362mm x 362mm 3 2mm opening b ThepowerM...

Page 6: ...unit as necessary Roof Gasket centers over 362mm x 362mm 3 2mm 3 Removeupperductfromceilingtemplateandlocate it over blower discharge See FIG 10 Note EdgewithoutflangeinstallstowardREARofopening 4 Use two 2 sharp pointed 10 sheet metal screws to hold duct to base pan Screw holes are provided in bottom of base pan for these screws 5 Reachupintoreturnairopeningoftheairconditioner and pull the unit s...

Page 7: ... kit 4 Carefullypushallexcesswirebackintothejunction box and install cover onto the box with two blunt screwsprovided 5 Plug the electrical conduit from the upper unit into the mating switch box connector See FIG 13 6 Wrap wire tie around plug connector s to prevent removal in field service FIG 13 Route Power Supply Through Romex Connector Plug Conduit Into Switch Box And SecureWithWire TieTo Prev...

Page 8: ...panelsintheairbox Washthe filters with soap and warm water let dry and then reinstall Note Never run the air conditioner without return air filter in place This may plug the unit evaporator coil with dirt and may substantially affect the performance of the unit 2 Clean air box housing and control panel with a soft cloth dampened with a mild detergent Never use furniture polish or scouring powders ...

Page 9: ...30 RoofMountAssembly Rear AirConditioner UpperDischarge Duct CeilingTemplate MountingBolts Air Box RoofOpening FIG 17 ...

Page 10: ...H C L1 4 2 1 MOTOR 2 HEAT ACCESSORY HEAT ACCESSORY BLK BLK BLK ELEMENT LIMIT SWITCH 3 1 WHT LIMIT SWITCH BOX JUNCTION JUNCTION LINE SPLICE LINE SPLICE FIELD WIRING FIELD WIRING FACTORY WIRING TSTAT TSTAT USE COPPER CONDUCTORS ONLY USE COPPER CONDUCTORS ONLY 220 240 VAC 50 HZ 10 220 240 VAC 50 HZ 10 3105580 025 FAN CAP FAN CAP ID ID BLK YEL RED BLU WHT WHT GR YL BLK YEL RED BLU WHT WHT GR YL BRN BR...

Reviews: