EN
CoolFreeze Operation
31
I
In HIGH mode, the battery monitor responds faster than at the levels “LOW”
and “MED” (see the following table).
CF11, CF16, CF26:
This is how to select the battery monitor mode (fig.
1
, page 3, fig.
2
,
page 3):
➤
Switch on the cooler.
➤
Press the “SET” button
(4)
three times.
➤
Use the “+”
(6)
and “–”
(7)
buttons to select the battery monitor mode..
✓
The selected mode then appears in the display for a few seconds. The
display flashes several times before it returns to the current temperature.
I
NOTE
When the cooling device is switched off by the battery monitor due
to low voltage, the display (fig.
2
5, page 3) switches off and the
“Power” LED (fig.
2
2, page 3) flashes orange.
Battery monitor mode
LOW
MED
HIGH
Cut-off voltage at 12 V
10.1 V
11.4 V
11.8 V
Cut-in voltage at 12 V
11.1 V
12.2 V
12.6 V
Cut-off voltage at 24 V
21.5 V
24.1 V
24.6 V
Cut-in voltage at 24 V
23.0 V
25.3 V
26.2 V
NOTE
When the cooler is supplied by the starter battery, select the bat-
tery monitor mode HIGH. When the cooler is connected to a sup-
ply battery, the battery monitor mode LOW will suffice.
If you wish to operate the cooling device from the AC mains, set
the battery monitor to LOW.