WIEGAND
This Wiegand section is not necessary if your DOLKSF1KB is standalone.
•
The wires for Wiegand
•
Yellow – D1, Wiegand DATA 1
•
Blue – D0, Wiegand DATA 0
•
Brown – BUZ, Buzzer control line, 0V active
•
Red – LED, Red LED control line, 0V active
•
Black – GND, Common ground
•
White – DATA, Data In/Out line, for decoder connection
PROGRAMMING CHART
DOLKSF1KB
Keypad Feature
Code Entry
Comments
Begin Programming
Mode (Solid Yellow)
[Master Code], *, *
Set System into Programming
Mode. The default Master Code is
0000.
Note: All of the following
commands must be keyed while in
Programming Mode.
End Programming Mode
*, *
Return to normal operation.
Set Master Code
01, [4-8 digit Master Code], #
Set your new Master Code.
Access Codes
Record Access Codes
(Output 1, 2, 3)
[Output Number: 1, 2, or 3], 02, [User number:
000-999], [4-8 digit Access Code], #
Set 4-8 digit code for general
access. Each unique 4-8 digit code
will require a new user number.
Important Note: It is important to
document your user numbers
because users can be deleted and
reassigned new codes for access.
Delete Access Codes
(Output 1, 2, 3)
[Output Number: 1, 2, or 3], 05, [User number:
000-999], #
Delete the user and remove their
Access Code.
Clear all Access Codes
[Output Number: 1, 2, or 3], 00999, #
Clear all Access Codes depending
on which output relay accessed.
Authorization Codes
Set Authorization Code
02, [4-8 digit Authorization Code], #
The Authorization Code is for the
owner to access the three outputs
of the keypad and to enable/disable
Access Lock.
Access output 1, 2, or 3
[Authorization Code], #, [Output: 1, 2, or 3]
Each output can be accessed with
one code.
Access Lock
[Authorization Code], #, 9
Entering the Authorization Code
during normal operation will toggle
Access Lock on. Entering the
Authorization Code again will
toggle Access Lock off.