Dolby Installation Guidelines
Unit Connections and Dimensions
2-4
2.3.2 Audio
Connections
The digital audio inputs and reference input are provided on female BNC connectors.
Input signals should be compliant with AES3-id-1995 (unbalanced, 75
Ω
, 1V peak-to-
peak standard output). AES3-id signals are very similar to analog composite video,
although dedicated AES3 distribution equipment should be used. If the loop-through
BNC connectors are not being used to feed additional equipment, terminate them with
a standard 75
Ω
video terminator.
The digital audio output is provided on a female BNC connector. The output is 75
Ω
,
unbalanced, with signal levels compliant with AES3-id-1995.
2.3.3
Serial I/O (Remote)
The DP563 allows remote control via the front-panel (RS-232) or rear-panel (RS-
485) ports. It is able to communicate at rates of 9.6 kbps, 19.2 kbps, or 38.4 kbps. The
unit address can be any discrete tributary address as specified in SMPTE RP 113-
1996. See Section 6.4 for further information. The default address is 8280, and the
serial I/O connections can also be used for software upgrades.
2.3.4 Auxiliary
Data
The Aux Data port is an RS-485 port that may be used for future enhancements. See
Section 5.2 for pin assignments.
2.4
DP569
Figure 2-4
Front and Back Panels of DP569
2.4.1 Dimensions
The DP569 occupies one rack unit and measures 44
×
483
×
324 mm (1.75
×
19
×
12.75 inches). Its net weight is 4.7 kg (10.3 lb).