DolbyRemote Installation and Operation
Dolby Digital Parameters
4-14
does not guarantee that a valid test tone will be produced at the output of the DP567
or DP569. Dolby Digital encoding must also be active, which requires that the
selected clock source be valid. The selection of a
Test Tone
mode automatically
overrides the input format settings. All other settings remain active.
4.5.5 Stream
Number
Input
Input
shows the input stream number for a pre-encoded signal present at the
reference input.
Output
Output
defines the stream number for the Dolby Digital output of the encoding
process. The default is zero. If multiplex mode is currently active, the selected stream
number cannot be identical to that of a stream currently being received.
4.6 Reference
Input
Figure 4-7
Reference Input
4.6.1 Reference
Input
Lock Status
Lock Status
shows whether the reference input has been detected and locked.
Sample Rate
Sample Rate
shows the sample rate of the reference input.
Integrity
Integrity
shows the data integrity of the reference input.