DOL 44R Technical User Manual Download Page 2

 

 

201

8

.0

9

.26

 •

 6

0

4

126

 •

 1

7

.0

9

 • 

EN

 •

 M

a

d

e

 in

 De

n

m

a

rk

 

dol-sensors a/s

           Hedelund 4, Glyngøre           7870 Roslev           Denmark           Tlf. +45 72 17 58 88           Fax +45 72 17 59 59           

www.dol-sensors.com

 

TECHNICAL USER GUIDE 

 

PRODUCT DESCRIPTION: 

DOL 44R is a capacitive relay sensor for 

detection of feed, grain and solids. The 

sensors have relay output including switch 

function. 

Fields of application: 
• Level control in silos and containers 
• Controlling the filling and emptying 

process. 

 

MOUNTING GUIDE (FIG. 1): 

DOL 44R includes M30 thread. Mount it in a 

ø30 mm hole and tighten using the locknuts 

included. 

 

DOL 44R is made in a ø30 mm smooth 

design mounted in a PG36/M40 gland. 

Figure1 

 

 

 

 

DOL 44R-G 

 

 

 

 

DOL 44R 

INSTALLATION GUIDE (FIG. 2): 

Supply voltage is connected to the blue and 

brown wire. 

The load is connected in series with the 

relay contact of the sensor. 

STOP

 by activating the sensor: Use the 

black wires 1 and 3. 

START

 by activating the sensor: Use the 

black wires 1 and 4. 

NOTE!

 The internal relay is in position NC 

when the supply voltage is connected and 

the sensor is activated - wire 1 and 4 are 

connected. 

 

Figure 2: No-current sensor 

 

 

 

USER’S GUIDE (FIG. 3): 

Depending on its type, DOL 44R has 

two trimmers with different 

functionalities. 

Delayed disconnection:

 

• Fixed time 

or

 

• Time adjustable on trimmer 

Delayed connection:

 

• Fixed time 

or

 

• Time adjustable on trimmer 

Sensitivity:

 

• Fixed distance 

or

 

• Distance adjustable on trimmer 

Max RunTimer:

 

• Settings on the trimmer: Off, Period 1, 

Period 2 

The actual functionality of the sensor is 

indicated on the product label. 

DOL 44R has a red LED, indicating 

sensor status. 

Fig. 3 shows examples of LED 

sequences.  

Figure 3 

 

 

 

 

DOL 44RH has a built-in, controlled heat 

function which prevents frost and 

condensation on the sensor. This 

ensures optimum detection in very cold 

and damp environments.  

The heat function is only possible for the 

90-265 V AC voltage version. 

TECHNICAL DATA: 

Supply voltage: 

Voltage version: 

 

90 - 265 VAC 

47 - 63 Hz 

Voltage version: 

 

10 - 30V AC/DC 

47 - 63 Hz 

Voltage version: 

 

20 - 280V AC/DC 

47 - 63 Hz 

Relay: 

Max. resistive load, 250VAC: 

5 A 

Max. lagging load, 250VAC:  

2 A 

Min. relay current, 12 VDC 

100 mA 

Temperature: 

Temp. operation: 

- 20 °C - + 70 °C 

- 4 °F - + 158 °F 

Temp. operation, USA 

and Canada: 

- 20 °C - + 65 °C 

- 4 °F - + 149 °F 

Temp. operation, 

storage: 

- 30 °C - + 80 °C 

- 22 °F - + 176 °F 

Temp. operation and 

storage with heat 

function: 

- 40 °C - + 70 °C 

- 40 °F - + 158 °F 

Degree of protection: 

IP: 

69k 

NEMA: 

1, 3, 4, 6, 12, 13 

Cable: 

Lenght: 

2 m 

6.6 feet 

Conductor dimensions: 

 

Style: 

5 x 0.5 mm

5 x AWG20 

UL2517 

Dimensions: 

 

 

Approvals: 

CE 

UL 

C-UL 

 

 

 

Blue
Brown
Black 1
Black 4
Black 3

10-30V
AC/DC
COM
NC
NO

Blue
Brown
Black 1
Black 4
Black 3

90-
265VAC
COM
NC
NO

NC(1-4)

NO(1-3)

NC(1-4)

NO(1-3)

NC(1-4)

NO(1-3)

Sensor

Ingen
tidsforsinkelse

Forsinket
frakobling

Forsinket
tilkobling

LED

LED

LED

Relay NC(1-4) 

 

 

 

Relay NO(1-3) after delay 

 

 

 

LED- sequence 

No time 
delay 

 

 

Delayed dis-
connection 

 

 

Delayed 
connection 

Reviews: