DOL 40R Series Technical User Manual Download Page 4

Technical User Guide

dol-sensors a/s  – Agro Food Park 15  – DK-8200 Aarhus N  – T: +45 7217 5888  – F: +45 7217 5959  – www.dol-sensors.com

5 Technical data

Electrical

Supply voltage 
variant depending

V AC/DC

V AC

10-30

90-250

Frequency

Hz

50 - 60

Relay switch max. current

V AC

250

Relay switch max. current
AC

A

5 A at cos φ = 1

2 A at cos φ = 0,8

0,35 A at cos φ = 0,4

Relay switch max. current
DC

A

5 A at 0-30 V DC

Safety

Relay switches and supply voltage are galvanically separated. Test

voltage 4 kV AC

Specifications

Variant understanding

DOL 45R G T

Thread 

Series

Tube mount 

Distance of activation

Adjustable 0-15 mm depending on material Factory setting is grain.

Time delay

Adjustable 0 - 240 min. Factory setting is 30 sec.

Mechanical

Sensor length

mm

(inches)

110 (4 5/16)

Sensor diameter

mm

(inches)

30 (1 3/16)

Cable dimensions

mm

2

(AWG)

5x 0,75 (5 x 18)

Cable length

m

1.5

Cable type

UL2517

Weight incl. cable

g

290

Environment

Operating temperature

°C (°F)

-20 - +70 (-4 - +158)

Storage temperature

°C (°F)

-30 - +85 (-22 - +185)

Protection class

IP

IP67

Approval

CE, C-UL & UL

5.1 Dimensions

603722 • 2022-08-12 • en-US • Made in Denmark

Summary of Contents for 40R Series

Page 1: ...40R Capacitive Relay Sensor For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com ...

Page 2: ...mounted so that at least 10 mm of the sensor end is free The DOL 40R series in a smooth design is mounted efficiently in a special gland additional accessory item number 140107 DOL 40R G The DOL 40R G series with M30 thread is mounted in a ø30 mm hole and is tightened with a locknut 3 Installation guide Installation servicing and troubleshooting of all electrical equipment must be carried out by q...

Page 3: ...s indicate when the switches are acti vated Green 0 2 mm 0 2 mm Sensitivity adjustment DOL 41R 43R 45R press 1 x A B simultaneously press A or B for 0 2mm 0 2mm DOL 41R settings is completed press A B DOL 43R and DOL 45R continue to the next setting by press A B Red 1 sec 1 min Time delay setting DOL 43R 45R Press A or B for 1 minute 1 seconds Eksempel 1xA 5xB 65 seconds DOL 43R settings is comple...

Page 4: ...e galvanically separated Test voltage 4 kV AC Specifications Variant understanding DOL 45R G T Thread Series Tube mount Distance of activation Adjustable 0 15 mm depending on material Factory setting is grain Time delay Adjustable 0 240 min Factory setting is 30 sec Mechanical Sensor length mm inches 110 4 5 16 Sensor diameter mm inches 30 1 3 16 Cable dimensions mm2 AWG 5x 0 75 5 x 18 Cable lengt...

Reviews: