DOL 130412 Technical User Manual Download Page 9

Technical User Guide

DOL 94-10

www.dol-sensors.com

9

8 Technical data

Electrical

Supply voltage

V DC

11 - 30

Power consumption max.

mA

50

Consumption

W

1.5

Load

MΩ

>0.5 - <10

Recommended load

>100

Output signal

V

0 kg = 0.5

10 kg = 10.00

Output impedance

<1

Mechanical

Cable dimensions

mm

Ø 6.8

Capacity

kg

0-10

Accuracy

%

0.3

Max. overload

%

150 of capacity

Environment

Temperature, operation

°C (°F)

-10 to +45 (+14 to 130)

Storage temperature

°C (°F)

-25 to +55 (-13 to +131)

Ambient humidity, opera-
tion

% RH

0-90

Protection class

IP

65 (spray-proof)

Shipment

Dimensions
H x Ø

mm

670, 220

Weight

g

2000

Shipping weight

g

2500

Summary of Contents for 130412

Page 1: ...DOL 94 10 Bird scale For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959...

Page 2: ...ct description DOL 94 10 poultry scale is capable of weighing animals up to 10 kg The weighing cell of the scale converts the weight of the bird to a voltage This voltage is intensified and ad justed...

Page 3: ...ug four pole female Cable plug four pole male Dust cap 693 female plug Dust cap 693 male plug 3 Mounting Guide 1 Place the scale on the floor and check that it is in a stable position where there is g...

Page 4: ...10 4 Recommended tools Below follows a list of tools recommended for installation of the DOL 94 10 Item Description Cordless drill Screwdriver bits Utility knife Multimeter Tape measure Side cutter N...

Page 5: ...onal standard EN 60204 1 and any other EU standards that are applicable in Europe The installation of a power supply isolator is required for each motor and power supply to facili tate voltage free wo...

Page 6: ...Technical User Guide 6 www dol sensors com DOL 94 10 5 3 Circuit diagram Example of poultry scale connected to production controller The exact connection depend on the other connections Poultry scale...

Page 7: ...r and dirt 5 Remove the rubber plug Press the button to start calibration Press the button to start calibration 1 Place the cap upside down on the end of the top frame so the electric module is uncove...

Page 8: ...sult of the settings for search limits and refer ence weight in the controller not being correct See also the User s Manual of the controller 7 1 Batch End Catching Remove the scale before catching Cl...

Page 9: ...utput signal V 0 kg 0 5 10 kg 10 00 Output impedance 1 Mechanical Cable dimensions mm 6 8 Capacity kg 0 10 Accuracy 0 3 Max overload 150 of capacity Environment Temperature operation C F 10 to 45 14 t...

Page 10: ...Technical User Guide 10 www dol sensors com DOL 94 10...

Page 11: ...Technical User Guide DOL 94 10 www dol sensors com 11...

Page 12: ...Technical User Guide dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com 604388 2020 07 29 en US Made in Denmark...

Reviews: