EN - DOL 25 SENSOR TECHNI

CAL USER’S GUIDE

 

Figure 9 

Sensor dimensions, Figure 9: 

Cable length 

 2 m 

Conductor dimensions 

4 x 0.26 mm

2

 (AWG22) 

Conductor colours 

Brown 

V+ 

Black 

NO output 

White 

NC output 

Blue 

V- 

M12 sensor plug 

1. V+
2. NC output
3. V-
4. NO output

Conductor colours and pin numbers are according to 
IEC60947-5-2. 

TECHNICAL DATA 

DOL 25 PNP/NPN 

DOL 25 SCR 

Supply voltage (Ue) 

10 

– 36 V DC 

Supply voltage (Ub) 

90-250 V AC

Max. ripple 

10 % 

Rated current (Ie) 

500 mA 

300 mA 

Voltage drop, output ON 

< 2.5 V 

< 10 V AC RMS 

Output function 

NC and NO 

NC or NO 

No-load supply current 

< 6 mA 

Time delay at start-up 

< 100 mS 

< 100 mS 

Time delay ON 

< 100 mS 

< 100 mS 

Time delay OFF 

0-600 sec.

0-600 sec.

Temperature, operation 

-20 - +70 ºC

-20 - +70 ºC

Temperature, storage 

-30 - +80 ºC

-30 - +80 ºC

Protection class 

IP67 

IP67 

Approvals 

CE and C-UL 

CE and C-UL 

Ø18 mm 

Ø30 mm 

Non-flushed 

Flushed 

Non-flushed 

Flushed 

Operating distance (

Sn

) adjustable 

0-10 mm

0-5 mm

0-20 mm

0-10 mm

Effective operating distance (Sa) 

0 ≤ Sa ≤ 0.8* Sn mm 

Repetition accuracy (R) 

5 % 

Hysteresis (H) 

< 0.15* Sn mm 

MAINTENANCE INSTRUCTIONS 

No maintenance is required. However, it may be necessary to clean around the sensor, if it is placed in a dirty 
environment 