EN - DOL 25 SENSOR TECHNI
CAL USER’S GUIDE
Figure 9
Sensor dimensions, Figure 9:
Cable length
2 m
Conductor dimensions
4 x 0.26 mm
2
(AWG22)
Conductor colours
Brown
V+
Black
NO output
White
NC output
Blue
V-
M12 sensor plug
1. V+
2. NC output
3. V-
4. NO output
Conductor colours and pin numbers are according to
IEC60947-5-2.
TECHNICAL DATA
DOL 25 PNP/NPN
DOL 25 SCR
Supply voltage (Ue)
10
– 36 V DC
Supply voltage (Ub)
90-250 V AC
Max. ripple
10 %
Rated current (Ie)
500 mA
300 mA
Voltage drop, output ON
< 2.5 V
< 10 V AC RMS
Output function
NC and NO
NC or NO
No-load supply current
< 6 mA
Time delay at start-up
< 100 mS
< 100 mS
Time delay ON
< 100 mS
< 100 mS
Time delay OFF
0-600 sec.
0-600 sec.
Temperature, operation
-20 - +70 ºC
-20 - +70 ºC
Temperature, storage
-30 - +80 ºC
-30 - +80 ºC
Protection class
IP67
IP67
Approvals
CE and C-UL
CE and C-UL
Ø18 mm
Ø30 mm
Non-flushed
Flushed
Non-flushed
Flushed
Operating distance (
Sn
) adjustable
0-10 mm
0-5 mm
0-20 mm
0-10 mm
Effective operating distance (Sa)
0 ≤ Sa ≤ 0.8* Sn mm
Repetition accuracy (R)
5 %
Hysteresis (H)
< 0.15* Sn mm
MAINTENANCE INSTRUCTIONS
No maintenance is required. However, it may be necessary to clean around the sensor, if it is placed in a dirty
environment