Technical User Guide

DOL 45R-T

www.dol-sensors.com

3

4 User Guide

Activated

Not active

Red

Green

Sensor

No time delay

Delayed

disconnection

Delayed

connection

Red

Red

Green

Green

DOL 41R

 has no time delay.

DOL 43R

 has an option for delayed disconnection. Time delay

starts When the activation stops (red flash) When this time stops,
the relay switches back.

DOL 45R

 has Apart from the settings mentioned above, also has

the option of delayed connection. The time delay starts when the
sensor is affected. When the delay period runs out, the relay will
switch. The relay does not switch back until the activation stops.

Sensitivity

Delayed disconnection Delayed connection

41R

43R

45R

DOL

The sensitivity and the delay length are adjusted by two switches. LEDs indicate when the switches are acti-
vated.

Green-0.2 mm

+0.2 mm

Sensitivity adjustment (DOL 41R / 43R / 45R)

press 1 x A+B simultaneously
press A or B for -0,2mm +0,2mm
DOL 41R settings is completed press A+B
DOL 43R and DOL 45R continue to the next setting by press A+B

Red

+1 sec.

+1 min

Time delay setting (DOL 43R/45R)

Press A or B for +1 1 seconds
Eksempel 1xA + 5xB = 65 seconds
DOL 43R settings is completed press A+B
DOL 45R continue to the next setting by press A+B

Yellow

On

Off

On / off delay (DOL 45R)

press A or B for delayed on or off
press A+B simultaneously = settings completed

Status

Red: sensor is affected
Green: sensor is unaffected
Yellow: Error
Flash: ​Time delay

Special functions

Factory setting: Hold A + B simultaneously for 15 seconds
Show delay Hold A + press 2xB (Red = 1 min. Green = 1 sek.)
Change delay: Hold A + press 4xB (+10 sec.) hold A + 5+B (÷5 sec.)
Hold A + 6+B (+1 hour.)
Switch off delay.: Hold A + press 7xB
switch off LED Hold A + 8xB
Switch on LED Hold A + 9xB