Doheny's 7816 Installation, Operation & Parts Download Page 2

10411 80th Avenue Pleasant Prairie, WI 53158 | Orders and Customer Care: 1-800-574-7665 | Fax: 1-800-323-5932 | Doheny.com 

Symbol means:

DANGER

 

  Indicates  that  if  failure  to  avoid  potential  hazard,   

 

will

 cause severe personal injury or death or  

  property damage.

WARNING

 

  Indicates  that  failure  to  avoid  potential  hazard,  

 

could

 result in severe personal injury or death or  

  property damage.

CAUTION

 

  Indicates that failure to avoid potential hazard, 

will  

  or could

 cause moderate personal injury or 

 

  property damage.

INSPECTION

 

Examine the equipment when received. Notify your  

  dealer or carrier of any damage or missing parts.  

  Verify that equipment is of size and model specified.  

CHAPTER 1

:

IMPORTANT SAFETY INSTRUCTIONS

 

When installing and using this electrical equipment,  

 

basic safety precautions should always be followed,  

  including the following: 

READ AND FOLLOW ALL INSTRUCTIONS
▲WARNING  Pay Attention to Children.

1.  To reduce risk of injury, do not permit children to use  

  or climb on this product. Closely supervise children  

  at  all  times.  Components  such  as  the  filtration  

  system, pumps, and heaters must be positioned to  

  prevent children from using them as a means of  

  access to the pool.

▲WARNING  For cord & plug connected units

2. Risk of Electrical Shock. Connect only to a 

 

  grounding type receptacle protected by a ground- 

  fault circuit-interrupter (GFCI). Contact a qualified  

  electrician if you cannot verify that the receptacle is  

  protected by a GFCI.

▲WARNING  For cord & plug connected units

3.  Do not bury cord. Locate cord to minimize abuse  

  from lawn mowers, hedge trimmers and other  

 equipment.

▲WARNING  For cord & plug connected units

4. To reduce the risk of electric shock, replace 

 

  damaged cord immediately.

▲WARNING  For cord & plug connected units

5.  To reduce the risk of electrical shock do not use  

  an extension cord to connect unit to electrical  

  supply; provide a properly located outlet.

▲CAUTION  For  pumps  with/without  3-ft  (91m)  

  cord or 6-ft (1.82m) cord

6.  This pump is for use with permanently installed  

  pools and may also be used with hot tubs and  

  spas if so marked. Do not use with storable pools.  

  A permanently installed pool is constructed in or  

  on the ground or in a building such that it cannot  

 

be readily disassembled for storage. A storable pool  

 

is constructed so that it may be readily disassembled  

  for storage and reassembled to its original integrity.

▲WARNING  For hot tub and spa pumps

7.  Do not install within an outer enclosure or beneath  

  the skirt of the hot tub or spa, unless so marked.

8. 

SAVE THESE INSTRUCTIONS

.

General Warnings

 

• Never open the inside of the drive motor enclosure.  

   There is a capacitor bank that holds a 230 VAC  

    charge even when there is no power to the unit.

  • The pump is not submersible.

  • The  pump  is  capable  of  high  flow  rates,  use  

   caution when installing and programming to limit  

   pumps performance potential with old or 

 

    questionable equipment. 

  • Code requirements for the electrical connection  

    differ  from  state  to  state.  Install  equipment  in  

    accordance with the National Electrical Code and  

    all applicable local codes and ordinances. 

  • Before servicing the pump; switch OFF power  

   to the pump by disconnecting the main circuit to  

    the pump. 

DANGER:

 Suction entrapment hazard: Stay off the  

  main drain and away from all suction outlets. This  

  pump produces high levels of suction and creates  

  a strong vacuum at the main drain at the bottom  

  of the body of water. This suction is so strong that  

  it can trap adults or children under water if they  

  come in close proximity to a drain or a loose or  

  broken drain cover or grate. The use of unapproved 

  covers or allowing use of the pool or spa when  

  when covers are missing,cracked or broken can  

 

result in body or limb entrapment, hair entanglement,  

  body entrapment, evisceration and/or death. The  

  suction at a drain or outlet can cause: 

  Limb  Entrapment: 

When a limb is sucked or  

  inserted into an opening resulting in a mechanical  

  bind or swelling. This hazard is present when the  

  drain cover is missing, broken, loose, cracked, or  

  not properly secured. 

  Hair Entanglement: 

When the hair tangles or knots  

 

in the drain cover, trapping the swimmer underwater.  

  This hazard is present when the flow rating of the  

  cover is too small for the pump(s). 

Summary of Contents for 7816

Page 1: ...ids warranty ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PUMP THAT MUST BE PROVIDED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY This equipment must be installed and serviced by a qualified technician Improper installation can create electrical hazards which could ...

Page 2: ...d pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage Astorable pool isconstructedsothatitmaybereadilydisassembled for storage and reassembled to its original integrity WARNING For hot tub and spa pumps 7 Do not install w...

Page 3: ...mming Pools Wading Pools Spas and Hot Tubs and either i A safety vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vaccum Release SVRS for Residential and Commercial Swimming Pools Spa Hot Tub and Wading Pool Suction Systems and or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems SVRS for Swimming pools Spas and Hot Tubs or ii A properly de...

Page 4: ...on to 1 Drainage away from pump 2 Ventilation of pump motor 3 Access for future servicing and winterizing 4 Protection from the elements CHAPTER 3 GENERAL PLUMBING For Solvent Weld Connection Rigid or flexible PVC pipe can be used Pipe ends should be clean and free of any flash caused by the cutting operation Be sure that the proper adhesive is used on the type of pipe specified Note A primer will...

Page 5: ...source of information Follow his recommendations and if these include draining the filter system proceed as follows 1 If your system does not contain a filter proceed to step 2 A For sand filters BACKWASH for 3 to 5 minutes and set dial valve to WINTERIZE B For cartridge filters Clean the filter element and store in a dry place 2 Drain system by loosening drain plugs drain plugs will drain without...

Page 6: ...lter 7 Impeller clogged 8 Wrong rotation 3 phase only Low Pump Pressure 1 Pump running at reduced speed see above 2 Wrong rotation 3 phase only 3 Discharge valve or inlet fittings closed too much High Pump Pressure 1 Discharge valve or inlet fittings closed too much 2 Return lines too small 3 Dirty filters Noisy Pump and Motor 1 Plugged basket in skimmer or hair in lint strainer 2 Worn motor beari...

Page 7: ...04080 Diffuser 2 7a 89106101 Impeller for 7816 1 7b 89106201 Impeller for 7817 1 8 65028026000 Seal Assembly 1 9 65431121080 O Ring 1 10 648910602080 Pump Cover 1 11 5225007000 Screw 3 8 16UNC 25 4mm 4 12 65244015000 Gasket M10 8 13 648910603080 Over Cover 1 14a 65023076000 1 0HP Motor for 7816 1 14b 65023077000 1 5HP Motor for 7817 1 15 5225008000 Screw 3 8 16UNC 50 8mm 4 16 647254205080 Supporti...

Page 8: ...use or care shall be replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays After 90 days to obtain warranty replacements defective components should be returned transportation paid to the place of purchase For further Doheny s service contact Doheny s cus tomer care department No returns may be made directly to the factory without the ex...

Reviews: