11.4 Interface converter (Option) 
 
Interface converter converts the electronic signal by opto coupler to opposite direction as below. 
Also it provides additional dry contact signals in both Normal Closed and Normal Open by the built-in relay. 
 

Summary of Contents for XS-38D

Page 1: ...Instructions manual XS 38D 1 XS 38D SERVICE MANUAL ...

Page 2: ...G G This information has to be kept in a location known by all users Each operator has to read carefully this manual before installing using and mending the product Be sure that the operator has understood using recommendations and the meaning of signs put on the product Most accidents could be avoided respecting this Manual Instructions As a matter of fact they were created according to European ...

Page 3: ... Mechanical specification p 6 5 Selectable INPUT VOLTAGE p 6 6 Pin configuration of output p 6 7 Selectable OUTPUT p 7 8 Soft start and Double hit p 7 9 Over Current Protection Overload over heat protection and reset p 8 10 Connections p 9 11 Interface with XS 38D controller p 10 11 1 Connector and cables p 10 11 2 Input Output signals interface p 10 11 3 Timing chart of start Stop signal p 10 11 ...

Page 4: ... will increase the risk of electric shock Do not abuse the cord Never use the cord to carry the tools or pull the plug from an outlet Keep cord away from heat oil sharp edges or moving parts Replace damaged cords immediately Damaged cords increase the risk of electric shock When operating a power tool outside use an outdoor extension cord marked W A or W These cords are rated for outdoor use and r...

Page 5: ... to control Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tools operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used on ano...

Page 6: ...tput 20 30 30 38 VDC selectable Rated power 2 5 A 95W Maximum output current 6 A Intermittent operation 10s On 30s Off Safety system CE certified Class I 4 Mechanical specification Size 98 x 158 x 55H mm Weight 850 gr Power cord 1 5 m Fuse 6 3 A 250 V 5 Selectable INPUT VOLTAGE 6 Pin configuration of output ...

Page 7: ...t Start during 0 2 sec Yellow Blink once 2nd Soft Start during 0 3 sec Yellow Blink twice 3rd Soft Start during 0 5 sec Yellow Blink three times 4th Soft Start during 0 6 sec Yellow Blink once four times 5th Soft Start during 0 8 sec Yellow Blink once 5 times 6th Soft Start during 1 0 sec Yellow Blink once four times 7th Double hit Red ...

Page 8: ...t current 12 13A Condition A Condition B Detection Time duration Immediately 3 sec 0 5 sec Protection Whole power shut down permanently Output power disappear for 5 sec LED No Protection Signal Buzzer No Normal frequent Beep ON OFF Higher frequent Beep ON OFF Recovery Turn off the power switch and on after 1 min Auto recovery after 5 sec ...

Page 9: ...Instructions manual XS 38D 9 10 Connections ...

Page 10: ...Instructions manual XS 38D 10 11 Interface with XS 38D controller 11 1 Connector and cables 11 2 Input Output signals interface 11 3 Timing chart of Start Stop signal ...

Page 11: ...4 Interface converter Option Interface converter converts the electronic signal by opto coupler to opposite direction as below Also it provides additional dry contact signals in both Normal Closed and Normal Open by the built in relay ...