DOD SR400D Manual Download Page 5

SECTION 1 - GETTING STARTED

Supplying Power

The SR 400 D, like any piece of computer hardware, is sensitive to voltage drops, 
spikes and surges. Interference such as lightning or power "brownouts" can seriously, 
and in extreme cases, permanently damage the circuitry inside the unit. Here are a 
few tips that will help you get the best possible performance out of your SR 400 D 
while avoiding damage:

• Always make sure you have a "clean" power source for connecting to

the SR 400 D. This means that the AC power line you connect to the SR 

400 D should be as free from voltage fluctuations and RF interference as 
possible. In recording environments, "clean" power is also important in 
preventing AC hum or buzz from getting to tape.

• Use a good quality spike / surge suppressor (also called a power strip).

This is an inexpensive solution to all but the most severe AC line 
conditions. A good quality power strip can save you a lot of money in
repair bills because they prevent large spikes and surges from reaching
your equipment racks. Also in this category (but more expensive) are 
rack mount power supplies. Some of these (such as the DOD 828), have
retractable light tubes and RF filtering.

• AC line conditioners offer the best protection from improper line voltages. 

Line conditioners constantly monitor the AC line for excessively high or low voltages 
and instantaneously compensate to deliver a consistent voltage to the connected 
equipment.

• Always make sure that your audio lines are as far as possible from

power cables. This will further prevent noise, hum, and stray 
magnetic fields from entering your signal path. If audio and power 
lines must run close to each other, try to avoid running them parallel
to one another.

Front Panel Controls

The front panel of the SR 400 D is laid out in a simple and straight forward way to 
make programming as easy as possible. Functions of each section are:

1)  BYPASS

- This button puts the SR 400 D into Bypass mode. This button also 

scrolls the display screen to the left when the SR 400 is in utility mode

2)  MODE

- This button lets you select the INPUT and OUTPUT modes of the SR 

400 D. The selections are: 1 IN and 2 Out or 2 IN and 2 Out. This button also scrolls 

11

10

9

8

7

6

5

4

3

2

1

Signal Processing

3

Signal Processing

SR 400D manual  6/8/99  10:54 AM  Page 3

Summary of Contents for SR400D

Page 1: ...Harman Music Group Inc S Visit DOD on the World Wide Web at http www dod com SR 400D manual 6 8 99 10 54 AM Page 1...

Page 2: ...ials and workmanship under normal use and service 3 DOD liability under this warranty is limited to repairing or replacing defective materials that show evidence of defect pro vided the product is ret...

Page 3: ...ns 4 Channel 1 XLR Input 4 Barrier Strip Input Connection 4 Channel 2 XLR Input 5 Channel 1 XLR Output 5 Barrier Strip Output Connection 5 Channel 2 XLR Output 5 Power Adapter Input 5 SECTION 2 PROGRA...

Page 4: ...t and output configurations with two independent programmable delays The SR 400 D also comes equipped with XLR and Barrier strip Inputs and Outputs as standard features Safety Precautions Do not open...

Page 5: ...but more expensive are rack mount power supplies Some of these such as the DOD 828 have retractable light tubes and RF filtering AC line conditioners offer the best protection from improper line volta...

Page 6: ...y unit 8 DELAY 2 This button is used to select Delay 2 for editing the delay unit 9 DATA WHEEL The Data Wheel is used to make edits to any of the selected functions 10 INPUT KNOB CHANNEL 1 Controls th...

Page 7: ...in 00 0m Max 697 651m Delay Feet Min 00 0 f Max 2288 88f Note The Maximum Delay in Feet and Meters will vary depending on the Temperature and Humidity settings These Delay units can be changed in the...

Page 8: ...he screen Now a lock icon will appear in the display indicating that the Delays are locked in place To unlock press and hold the Delay 2 button for approximately 5 seconds Temperature Unit Selection T...

Page 9: ...temperature Once selected the SR 400 D will re calculate and the correct Delay is heard Note This utility function can only be used when the Delay Unit is being measured in Feet or Meters Factory Res...

Page 10: ...Address 8760 S Sandy Parkway Sandy Utah 84070 USA declares that the product Product Name SR 400 D Product Options All with a Class II power adapter that conforms to the requirements of EN60065 EN6074...

Reviews: