9. OPERATINAL TEST

 

 

 

CHECKS IN TE EVENT OPERATIONAL FAILURE

 

In  some  situations,  operational  failure  can  arise  due  to  simple  causes  that  users  themselves  can  solve,  which  is  why  prior  to  requesting  the 
intervention of a specialised technician, we recommend that you carry out the following checks. 

The appliance does not work 

- Check that it is correctly plugged in. 
- Check that electricity reaches the power outlet. 

- Check that general switch is in the  

I/ON

 position. 

The internal temperature is too high 

Check that there is no heat source nearby. 

- Check that the grill is not obstructed. 
- Check the Set-point. 
- Check that the product loaded is perfectly distributed, without blocking the interior air ventilation exits and that the time elapsed since loading 
has been sufficient to chill the products. 

Check if the evaporator has ice. 

- Check that the condenser is not obstructed. 
- Check that the appliance is functioning normally.

 

In the event of strange or excessive noises 

- Check the levelling of the unit as this may cause vibrations. 
- Check that there is no object rubbing against any movable element of the refrigerated unit. 
 
 

 

NOISE TESTING

 

 

- The noise tests were performed in a room without any noise absorption elements and without any large item placed near to the refrigerated 
unit. 
- The noise levels registered in the acoustic test have been carried out in accordance with the ISO 230 to 235 standards. 

Leq 

(continuous level) is less than 70 dB. (A) 

Lp

 (acoustic pressure level) is less than 130 dB. (C) 

 
NOTE. (A) (C) Frequency weights. 
 

 

 

10. DECOMMISSIONING 

 

  

Decommissioning 

 

The refrigerator cabinet containing polyurethane foam , oil, plastic parts , metal parts and electrical and electronic components. When the life of 
the  furniture  has  come  to  an  end  and  is  necessary  to  remove  the  cabinet  for  destruction  or  partial  recovery  ,  the  user  is  responsible  for 
delivering the product to the collection specified by the local authority for recovery and recycling WEEE professionals, always respecting the 
laws in force . The manufacturer is responsible for recovery, treatment and disposal at end of product life , in direct way or through a collective 
system make possible . If the rules are violated specific sanctions , established autonomously , according to the laws of each state belonging to 
the EC and conformally linked to all who are subject to those rules apply 

  

  Dismantling furniture 

 

In accordance with the rules on waste disposal in force in each country and full respect for the natural environment , we recommend subdividing 
the different parts of the furniture according to the material , separately or eliminate back. This product contains HFC , ie , fluorinated gases with 
high value of greenhouse gas ( GWP). So: The component parts of the cooling circuit can not be cut or separated until the refrigerant gas has 
been extracted for recovery in a specialized center. 

 

 Declaration of conformity RoHS 

 

He declares under its own responsibility that the refrigerated cabinet to which this manual refers , meets the requirements of Directive 2002/95 / 
EC  /  (RoHS  )  In  all  homogeneous  materials  used  for  manufacturing  ,  the  possible  existence  of  lead,  mercury  ,  hexavalent  chromium  , 
polybrominated biphenyls (PBB ) and diphenyl ether (PBDE ) does not reach 0.01% by weight . This statement is based on statements of our 
suppliers of raw materials and components . 
 
 
 
 
 

Summary of Contents for VIS-10-125

Page 1: ...MANUAL DE USO Y MANTENIMIENTO VITRINA EXPOSITORA VIS USER AND MANTINANCE MANUAL SERVE OVER COUNTER VIS MANUEL D UTILISATION ET D ENTRETIEN VITRINE GAMME R FRIG R E VIS...

Page 2: ...manual de uso ESPA OL PAG 3 user manual ENGLISH PG 12 manual d utilisation FRAN AIS PAGE 21 DOCRILUC EMPRESA CERTIFICADA...

Page 3: ...turer s name Fabricant DOCRILUC S L CIF B 14644678 Direcci n Manufacturer s address Adresse CTRA C RDOBA M LAGA Km 75 800 LUCENA C RDOBA SPAIN Tipo de equipo Type of equipment Type d quipement VITRINA...

Page 4: ...IONES DE USO 5 PUESTA EN MARCHA 6 RECOMENDACIONES 7 PRECAUCIONES 8 MANTENIMIENTO 9 PRUEBAS DE FUCIONAMIENTO 10 RETIRADA DEL SERVICIO 11 ESQUEMA EL CTRICO 12 ESQUEMA FRIGOR FICO ANEXO NORMATIVA ANEXO I...

Page 5: ...os en la alimentaci n el ctrica Modificaciones o intervenciones no autorizadas Uso de recambios no espec ficos para el modelo Incumplimiento total o parcial de las instrucciones Incidencias motivadas...

Page 6: ...etida o a una bandeja extra ble manualmente PRIMERA LIMPIEZA Primero retire el film protector del acero utilizando alg n objeto no punzante y retirando los restos de adhesivo con alcohol Evitar absolu...

Page 7: ...ORAS est n preparadas para la conservaci n de productos frescos o alimentos precocinados as como la refrigeraci n de bebidas El rango de temperaturas del equipo debe ser seleccionado considerando los...

Page 8: ...as como la debida protecci n del magneto t rmico y diferencial La red de alimentaci n debe tener la secci n adecuada para el consumo del aparato Si varios equipos se instalan alineados deben ser conec...

Page 9: ...r fico Desconectar el interruptor general y desenchufar la unidad Limpiar interior y exterior del aparato Abrir parcialmente la puerta para permitir la circulaci n de aire y de este modo evitar malos...

Page 10: ...duros o punzantes Para la limpieza de la bater a o de la carcasa NO se deben utilizar desengrasantes qu micos con componentes cidos o lej as cloro o amon aco as como las sales ya que todos estos produ...

Page 11: ...bre el modelo n mero de serie y matr cula indicados en la placa de caracter sticas 10 RETIRADA DEL SERVICIO Retirada del servicio El mueble frigor fico contiene espuma de poliuretano aceite elementos...

Page 12: ...11 ESQUEMA EL CTRICO o MODELOS VIS 10 125 VIS 90 VIS 10 190 o MODELOS VIS 9 125 1E VIS 9 125 2E...

Page 13: ...12 ESQUEMA FR O...

Page 14: ...l suave aire comprimido o un equipo de aspiraci n adecuado para no da arlos Ubique el equipo en una estancia amplia para evitar la posible formaci n de mezcla explosiva de gas y aire en caso de escape...

Page 15: ...RACTERISTICS AND CONDITIONS OF USE 5 START UP 6 RECOMMENDATIONS 7 PRECAUTIONS 8 MAINTENANCE 9 OPERATIONAL TESTS 10 DECOMMISSIONING 11 ELECTRIC SHEME 12 COLD SHEME ANNEX NORMATIVE ANNEX INSTALLATION IN...

Page 16: ...chased unit Possible damage to person of property caused by improper installation Installation not carried out following the procedures described in this manual Defects in the electricity supply Unaut...

Page 17: ...drain cleaning we recommend connecting it directly to the appropriate device or a receptacle should be positioned in order to collect the water FIRST CLEANING First of all remove the protective film...

Page 18: ...r pre cooked foods as well as the refrigeration of drinks The range of temperatures of the unit must be selected taking into account the following points Type of product for refrigeration or conservat...

Page 19: ...differential magnetic protection The power supply must have the suitable section for the consumption of the appliance If various units are installed in a row each one must be connected independently...

Page 20: ...ion of air The maximum weight for glass shelf will is 8 kg m distributed evenly and 60kg m for shelf exposure When the unit has to be turned off for a long period of time the following steps are recom...

Page 21: ...ng DO NOT use chemical de greasers with acid compounds or bleach chlorine ammonia or salts as all these products aggressively attack copper and aluminium Only water with well diluted neutral detergent...

Page 22: ...refrigerator cabinet containing polyurethane foam oil plastic parts metal parts and electrical and electronic components When the life of the furniture has come to an end and is necessary to remove t...

Page 23: ...11 ELECTRIC SCHEME o VIS 10 125 VIS 90 VIS 10 190 MODELS o VIS 9 125 1E VIS 9 125 2E MODELS...

Page 24: ...12 COOLING SCHEME...

Page 25: ...ompressed air or suitable suction equipment for not damaging them Place the equipment in a large room to avoid the possible formation of explosive gas air mixture in case of leakage The room must have...

Page 26: ...CONDITIONS D UTILISATION 5 MISE EN MARCHE 6 RECOMMANDATIONS 7 PR CAUTIONS 8 ENTRETIEN 9 TEST DE FONCTIONNEMENT 10 RETRAIT DE SERVICE 11 SCH MA LECTRIQUE 12 SCH MA FROID ANNEXE R GLEMENT ANNEXE INSTALL...

Page 27: ...roc dures d crites dans ce manuel D fections de l alimentation lectrique Modifications ou interventions non autoris es Utilisation de pi ces de rechange n tant pas sp cifiques au mod le Non observatio...

Page 28: ...nettoyage de vidange il est conseill de se connecter un r seau de branchement ou un plateau amovible manuellement PREMIER NETTOYAGE Enlever d abord le film prot geant l acier avec l aide d un objet n...

Page 29: ...s servant conserver des produits frais ou des aliments pr cuisin s ainsi qu conserver au froid les boissons La plage de temp rature de l appareil doit tre choisie au regard des points suivants Type de...

Page 30: ...r magn tothermique et diff rentiel Le r seau d alimentation doit tre dot d une partie qui servira la consommation de l appareil Si plusieurs appareils sont align s ils doivent tre connect s au r seau...

Page 31: ...nt une longue dur e il faudra suivre les consignes suivantes Enlever les produits de l int rieur du frigidaire D brancher l interrupteur g n ral et d brancher l unit Nettoyer l int rieur et l ext rieu...

Page 32: ...faut PAS utiliser des d graissants chimiques base de composants acides de javel de chlore ou d ammoniaque ni des sels tant donn que tous ces produits nuisent et agressent le cuivre et l aluminium Il...

Page 33: ...suivantes mod le num ro de s rie et immatriculation figurant sur la plaque des caract ristiques 10 RETRAIT DE SERVICE D classement L armoire de r frig rateur contenant une mousse de polyur thane l hu...

Page 34: ...11 SCH MA LECTRIQUE o VIS 10 125 VIS 90 VIS 10 190 MODELES o VIS 9 125 1E VIS 9 125 2E MODELES...

Page 35: ...12 SCH MA FROID...

Page 36: ...ir comprim ou une quipe d aspiration appropri pour ne pas les endommager Placez l appareil dans une grande salle pour viter la formation possible de m lange gaz air explosif en cas de fuite La chambre...

Page 37: ...72x1083 900x971x734 Refrigerated shelf area m2 1 17 1 79 0 48 Total display area m2 1 27 1 94 0 68 Visibility of products by arc method m2 0 57 0 87 0 31 Net volume l 176 270 107 Maximum load in shelf...

Page 38: ...8 Refrigerated shelf area m2 1 28 1 7 Total display area m2 1 2 1 36 Visibility of products by arc method m2 0 5 0 89 Net volume l 304 405 Maximum load in shelf kg 30 30 Location of the temperature se...

Page 39: ...EX INSTALLATION ANNEXE INSTALLATION Siempre atornille manualmente no utilice herramientas el ctricas Always screw manually do not use electrical tools Toujours visser manuellement ne pas utiliser d ou...

Page 40: ...3 4...

Page 41: ...Deje funcionando la vitrina 1 hora sin producto Leave working serve over counter 1 hour without product Laissez la fen tre en cours d ex cution 1 heure sans produit 5 6 1 2 3...

Page 42: ...ANEXO REGULACI N PLANO EXPOSICI N SOLO VIS 10 125 190 ANNEX DISPLAY AREA REGULATION ONLY VIS 10 125 190 ANNEXE R GLEMENT DE LA SURFACE D EXPOSITION SEUL VIS 10 125 190 4 7 11 1 2 0...

Page 43: ...3...

Page 44: ...Ctr C rdoba M laga km 75 800 Apartado de correos 515 14 900 Lucena C rdoba Espa a Telf 0034957510126 Fax 0034957510682 Info docriluc es www docriluc es...

Reviews: