All the accessories and protectors comply with the same requirements, including all fastenings, nuts and bolts, which will be made of 
stainless or zinc-based steel. 

The refrigerated unit is designed to be operated using ecological gas refrigerant, approved by the current CE standards. 

 

COMPOSITION OF THERMAL INSULATION 

The thermal insulation is made from expanded polyurethane 40 kg/m

3

, with expansive agent C4H5F5. 

 

REFRIGERANT 

Refrigeration: R-134ª. 

 

 

5. START-UP 

 

FIRST CLEANNING 
 

 

Clean the unit before connecting to the electricity supply. 

 

INSPECTION 
 

 

Check that the voltage and power line frequency coincide with those indicated on the specification plate of the 
appliance. 

 

The unit should not be used in threatening atmospheric or fire risk conditions. 

 

Check that there are no defects on the unit resulting from its transportation. The manufacturer will not be liable for 
damage suffered during transportation or arising from incorrect storage. 

 

Check the operation of the moving components of the unit. 

 

GENERAL CONNECTIONS 

 

 

Be sure the power cable is not damaged. 

 

If the power cable is damaged it must be replaced by another type H05-VV-F  or H05-VVH2-F.  This repair must be 
performed by qualified personnel. 

 

It is essential that the electrical installation to which the unit is going to be connected has an EARTH LEAD, as well as 
the necessary thermal and differential magnetic protection. 

 

The power supply must have the suitable section for the consumption of the appliance. 

 

If various units are installed in a row, each one must be connected independently to the power supply, avoiding the use 
of extension leads or multiple plugs. 

 

The manufacture disclaims all liability in the event that any of the above points are not followed. 

 

OPERATING ELEMENTS AND INDICATORS 
 

 
TURN ON/ OFF  

 
 

Press                            until appear 

ON

 to turn on the unit. 

 
 
To turn off the computer press the button for 5 sec until appear 

OFF

 and the condensing unit will stop working. 

 

 

Check set point 

 

 
 
 

  One  the  inside  of  the  unit  is  clean,  connect  the  power  supply 

and place the switch in the 

I/ON 

 position. The switch should 

be  lit  up.

 

The  thermostat  display  shows  the  air  temperature 

inside the unit. 
 

  Three minutes after turning on the switch, the LED showing the 

compressor is working will light up permanently. 
 

  The  initial  temperature  that  is shown  on  the  thermostat  display 

will  be  the  ambient  temperature.  As  the  machine  works,  the 
temperature  will  reduce  until  it  reaches  its  operating 
temperature. 
 

 

COMPRESSOR

 

THERMOSTAT

 

FAN

 

GÉNÉRAL SWITCH

 

Summary of Contents for ENFRIADOR-AGUA

Page 1: ...MANUAL DE USO Y MANTENIMIENTO ENFRIADOR DE AGUA USER AND MANTINANCE MANUAL WATER COOLER MANUEL D UTILISATION ET D ENTRETIEN REFROIDISSEUR D EAU...

Page 2: ...manual de uso ESPA OL PAG 3 user manual ENGLISH PG 10 manual d utilisation FRAN AIS PAGE 17 DOCRILUC EMPRESA CERTIFICADA...

Page 3: ...53 2 Fabricante Manufacturer s name Fabricant DOCRILUC S L CIF B 14644678 Direcci n Manufacturer s address Adresse CTRA C RDOBA M LAGA Km 75 800 LUCENA C RDOBA SPAIN Tipo de equipo Type of equipment T...

Page 4: ...SO 5 PUESTA EN MARCHA 6 RECOMENDACIONES 7 PRECAUCIONES 8 MANTENIMIENTO 9 PRUEBAS DE FUCIONAMIENTO 10 RETIRADA DEL SERVICIO 11 ESQUEMA EL CTRICO 12 ESQUEMA FR O CARACTER STICAS T CNICAS INSTALACI N PIE...

Page 5: ...anual Defectos en la alimentaci n el ctrica Modificaciones o intervenciones no autorizadas Uso de recambios no espec ficos para el modelo Incumplimiento total o parcial de las instrucciones Incidencia...

Page 6: ...IER OTRO AGENTE ABRASIVO Tenga especial cuidado con no mojar las partes el ctricas ATENCI N Para limpiar el ACERO INOXIDABLE no deben utilizarse esponjas de hierro n quel ni siquiera dejarlas apoyadas...

Page 7: ...onal t cnico cualificado Es imprescindible que la instalaci n el ctrica donde se vaya conectar el mueble disponga de TOMA TIERRA as como la debida protecci n de magneto t rmico y diferencial La red de...

Page 8: ...o desenchufar la unidad de la red el ctrica apagando antes el interruptor general y despu s el enchufe NO debe ser manipulado por ni os personas con disminuci n de capacidades mentales sensoriales o p...

Page 9: ...0 a la 235 Leq nivel continuo es menor de 70 dB A Lp nivel de presi n sonora es menor de 130 dB C NOTA A C Las ponderaciones frecuenciales En caso que dichos controles hayan dado resultado negativo di...

Page 10: ...podr n ser cortadas ni separadas hasta que se haya extra do el gas refrigerante para su recuperaci n en un centro especializado Declaraci n de conformidad RoHS Declara bajo su propia responsabilidad...

Page 11: ...11 ESQUEMA EL CTRICO 11 ESQUEMA FR O...

Page 12: ...CONDITIONS OF USE 5 START UP 6 RECOMMENDATIONS 7 PRECAUTIONS 8 MAINTENANCE 9 OPERATIONAL TESTS 10 DECOMMISSIONING 11 ELECTRIC SHEME 12 COLD SHEME TECHNICAL CHARACTERISTICS INSTALLATION INTERCHANGE PA...

Page 13: ...by improper installation Installation not carried out following the procedures described in this manual Defects in the electricity supply Unauthorised modifications or interventions Use of spares not...

Page 14: ...rying it afterwards DO NOT USE ANY DETERGENTS ANY PRODUCT CONTAINING CHLORIDE SULPHIDE OR ANY OTHER ABRASIVE AGENTS ALWAYS KEEP ELECTRIC PARTS AWAY FROM WATER ATTENTION Please do not use iron nickel s...

Page 15: ...VH2 F This repair must be performed by qualified personnel It is essential that the electrical installation to which the unit is going to be connected has an EARTH LEAD as well as the necessary therma...

Page 16: ...of adapters extension leads or multiple plugs Before carrying out any cleaning or maintenance operation unplug the unit from the electricity supply first turning off the main switch and then unpluggi...

Page 17: ...ondenser is not obstructed Check that the appliance is functioning normally In the event of strange or excessive noises Check the levelling of the unit as this may cause vibrations Check that there is...

Page 18: ...ject to those rules apply Dismantling furniture In accordance with the rules on waste disposal in force in each country and full respect for the natural environment we recommend subdividing the differ...

Page 19: ...11 ELECTRIC SCHEME 12 COLD SCHEME...

Page 20: ...ONS D UTILISATION 5 MISE EN MARHCE 6 RECOMMANDATIONS 7 PR CAUTIONS 8 ENTRETIEN 9 TEST DE FONCTIONNEMENT 10 RETRAIT DE SERVICE 11 SCH MA LECTRIQUE 12 SCH MA FROID CARACT RISTIQUES TECHNIQUES INSTALLATI...

Page 21: ...ons Incidents dus la soci t de transport ou au d placement de l appareil sur le lieu de l installation Tous les vents doivent tre libres de toute obstruction et ne sont pas couverts par le panneau d c...

Page 22: ...de fer peuvent se coller et produire une couche de rouille par contamination ce qui mettrait en danger une bonne hygi ne BRANCHEMENT DES TUYAUX Il est recommand que la connexion des tuyaux tant pour l...

Page 23: ...joncteur magn tothermique et diff rentiel Le r seau d alimentation doit tre dot d une partie qui servira la consommation de l appareil Si plusieurs appareils sont align s ils doivent tre connect s au...

Page 24: ...ttoyage ou d entretien d brancher l unit du r seau lectrique en teignant d abord l interrupteur g n ral et ult rieurement la prise L appareil ne doit pas tre manipul par des enfants ou des personnes q...

Page 25: ...rifier aussi que le temps coul depuis que le chargement est l int rieur est suffisant pour refroidir les produits V rifier si l vaporateur a glace V rifier que le condenseur est exempt de poussi re V...

Page 26: ...sont soumis ces r gles sont D montage des meubles Conform ment aux r gles en mati re d limination des d chets en vigueur dans chaque pays et le plein respect de l environnement naturel nous vous recom...

Page 27: ...11 SCH MA LECTRIQUE 12 SCH MA FROID...

Page 28: ...ERISTICS CARACT RISTIQUES TECHNIQUES Model Large mm Heigt mm Depth mm Frig Power W Capacity l Range C Open flow faucet l h T 10 C EAP 100H EAPI 100H 1405 580 563 485 100 1 3 79 EAP 175V EAPI 175V 878...

Page 29: ...t venta o por el fabricante The installation must be have as per the electrotechnical regulations of low tension If the supply wire is damaged it must be replaced by a cord or special set provided by...

Page 30: ...PIEZAS DE REPUESTO INTERCHANGE PARTS PI CES DE RECHANGE...

Page 31: ...Ctr C rdoba M laga km 75 800 Apartado de correos 515 14 900 Lucena C rdoba Espa a Telf 0034957510126 Fax 0034957510682 Info docriluc es www docriluc es...

Reviews: