Make sure that the first measurement 
and the distance to be measured are at 
right angle.Use the Minimum / 
maximum function, as explained in 
"Measuring -> Minimum / maximum 
measurement".

Press this button once, the display 

shows  . The laser is switched on.

Aim at the upper point ( 1 ) and trigger 

the measurement. After the first 
measurement the value is adopted.  The 
result is displayed in the summary line, 
the partial results in the secondary line.   
( e.g. Angle and Hypotenuse distance ) 

Press and hold down this button to 

trigger continuous measurement, sweep 
the laser back and forth, up and down 

Indirect measurement - 
determining a distance using 2 
auxiliary measurements

e.g. for measuring building heights.  It is 
helpful to use a tripod.

If the angle is above 

45°

, it need to 

measure point ( 2 ) . Press

 

to switch off 

the angle sensor, then must measure the 
distance of point ( 1 ). Keep the 
instrument as horizontal as possible 
during the measuring.

 

 

勾股

测量

=

设置

测量

26

EN

Function

MEASURE

MEASURE

=

MENU

Summary of Contents for DM6-80m

Page 1: ...Distance Beyond Handheld Laser Distance Meter Shenzhen Dobiy Electronic Co Ltd www dobiy com Laser Distance Meter DM6 MAX MIN ON MEASURE MENU TIMER CLEAR OFF Shenzhen Dobiy Electronic Co Ltd...

Page 2: ...English Congratulations on the purchase of our product Carefully read the Safety Instructions and the User Manual before using this product The person responsible for the instrument must ensure that...

Page 3: ...tuation or an unintended use which if not avoided may result in minor injury and or in appreciable material financial and environmental damage WARNING CAUTION Important paragraphs which must be adhere...

Page 4: ...out modificat ion or con version of the product Use after misapp ropriation Use of accessories fr om other man ufact ures w ithout the ex press approval Deliber ate or irresponsible behaviour on sca f...

Page 5: ...esigned for use in areas permanently habitable by humans do not use the product in explosion hazardous areas or in aggressive environments Responsibilities of the manufacturer of non original equipmen...

Page 6: ...or the safety of the equipment when in use The person in charge of the instrument has the following duties To understand the safety instructions on the product and the instructions in the User Manual...

Page 7: ...Make sure the optics is kept clean and that there is no mechanical damage to the bumpers In using the instrument for distance measurements or for positioning moving objects e g cranes building equipme...

Page 8: ...em to the collecting points provided in accordance with national or local regulations Dispose of the product appropriately in accordance with the national regulations in force in your country Always p...

Page 9: ...uipment The product conforms to the most stringent requirements of the relevant standards and regulations Yet the possibility of it causing interference in other devices cannot be totally excluded Nev...

Page 10: ...stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex Looking directly into the beam with optic...

Page 11: ...ce the batteries when the symbol 10 Labeling Start up EN Start Made in China AVOID EXPOSURE Laser radiation is emitted from this aperture Dobiy Electronic Co Ltd www doby com cn Dm6 Original laser dis...

Page 12: ...ore any long period of non use to avoid the danger of corrosion Multifunctional end piece The instrument can be adapted for the following measuring situations For measurements from an edge fold out th...

Page 13: ...nce button Angle button Marking Menu Confirming Storage button Background light Timing button Clear off button Pythagoras proposition button button Display 12 MEASURE MENU TIMER CLEAR OFF 1 Laser acti...

Page 14: ...surements 12 Stake out function 13 Error operating indication Battery power Instruction Supply Standard Components Battery power is 100 Battery power is 75 Battery power is 50 Battery power is 25 Batt...

Page 15: ...al requirements General description button pressed long You are in the MENU the units set and the first menu item Unit are displayed button pressed short pages through each menu item or button to make...

Page 16: ...following units are available m meter ft feet in inch ft in feet inch 1 16 button pressed long the instrument will remember of the current state or Beep button pressed long You are in the MENU button...

Page 17: ...ment Press the key and hold to switch the device and Laser continuous operation off Measuring with the tripod The reference must be appropriately adjusted in order to be able to take correct measureme...

Page 18: ...y CLEAR button The last action is canceled While making area or volume measurements each single measurement can be deleted and remeasured in series Reference setting The default reference setting is f...

Page 19: ...current state Not including Type DM2 Measuring Single distance measurement Press to activate the laser Press again to trigger the distance measurement The result is displayed immediately Tit measurem...

Page 20: ...otenuse distance and angle will be on the auxiliary display Not including Type DM2 Horizontal measurement Press this button to set a 5 second time delay Or press and hold down this button until the de...

Page 21: ...horizontal distances minimum values or the difference of maximum and minimum Press and hold down this button until you hear a beep Then slowly sweep the laser back and forth up and down over the desir...

Page 22: ...be displayed in the summary line while the previous one displayed in the secondary line This function is also available for area and volume measurement The next measurement is added to the previous on...

Page 23: ...The symbol appears in the display Press this button to take the first length measurement e g length Press this button to take the second length measurement e g width Press this button to take the thi...

Page 24: ...on Two different distances a and b can be entered into the instrument and can then be used to mark off defined measured lengths e g in the construction of wooden frames Entering stake out distances Pr...

Page 25: ...ntered using or he defined value b is confirmed with the button Pressing the button starts the laser measurement The display shows required stake out distance in the summary line between the stake out...

Page 26: ...measurement Pythagoras proposition The instrument can calculate distances using Pythagoras proposition All target points must be in a horizontal or vertical plane The best results are achieved when t...

Page 27: ...summary line the partial results in the secondary line e g Angle and Hypotenuse distance Press and hold down this button to trigger continuous measurement sweep the laser back and forth up and down I...

Page 28: ...l target point Press to stop continuous measurement point 2 The result is displayed in the summary line the partial results in the secondary line e g Hypotenuse and right angle edge distance 27 EN Fun...

Page 29: ...of picture 1 you need press button to switch off the angle sensor then through the three sides to determine the distance If the measurement is the horizontal distance fix the instrument Let the light...

Page 30: ...own this button to trigger continuous measurement Sweep the laser up and down over the ideal target point 2 Press to stop continuous measurement 2 The value is adopted press this button to trigger the...

Page 31: ...or long time The icon will show on the display and the previous 20 results measurements or calculated results are shown in reverse order The buttons can be used for navigation Make it available consta...

Page 32: ...ration change a better surface reflecting or using target plate The goal of the ambient light is too strong Change the light for measuring Temperature too high 40 or too low 0 Cool down or Warm up the...

Page 33: ...irect measurement Pythagoras proposition Plus minus method Continuous measurement Minimum maximum measurement Display illumination Show beep Multifunctional end piece Automatically Manual Protection a...

Page 34: ...At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a target plate to increase the measurement range during daylight or if the target has poor re...

Page 35: ...cleaning and maintaining this instrument according with our company s use of instrument and maintaining it at good technical condition This means that the tools can only use the original parts and sp...

Page 36: ...iy Electronic Co Ltd Zone B 5th Floor Longsheng Commercial Building Heping West Road Big Wave Street Longhua Town Bao An District Shenzhen 518000 CHINA Tel Fax 86 755 28896960 www doby lasers com 86 7...

Reviews: