![DNT XLP77 Service Manual Download Page 11](http://html1.mh-extra.com/html/dnt/xlp77/xlp77_service-manual_2514671011.webp)
2. Adjust Deviation
Step
Setting
Connection
Adjuster
Adjust for
1
AF Modulation adjustment
Channel
PMR: (P1) 446.00625 MHz
LPD: (69) 434.775 MHz
Mic : Transmit
Volume : Optional
Squelch : Optional
-Connection the audio generator
(set to 1 KHz)to the microphone
jack.
-Connect the modulation meter
through the RF attenuator to the
ANT jack.
-Adjust the audio signal level to obtain
by 1.5 KHz deviation. When you
increase the audio Signal by 20 dB,
the deviation Should not exceed 2.5
KHz deviation (Figure 3)
RV701
* For PMR:
2.3 ~ 2.5KHz
Normal Adjust:
2.5KHz
* For LPD:
4.5~5.0KHz
Normal Adjust:
5.0KHz
Figure 3