A.
CONNECTING THE GTP-32 UNIT TO THE BREAKOUT PANEL.
Look at the back of the GTP-32 unit and note the legend under the 37 pin I/O connectors. The breakout panel
has two sets of 37 pin connectors, one set is labeled GPI & GPO and the other set is labeled GPIO. Connect the
furnished 37 pin interconnect cable to the matching connector on the breakout panel and the GTP-32 unit.
Connect all 4 cables to their respective connectors.
Example 1:
Legend on GTP-32 unit = GPOI 1-8; connect to GPOI 1-8 connector on breakout panel.
Legend on GTP-32 unit = GPOI 9-16; connect to GPOI 9-16 connector on breakout panel
Legend on GTP-32 unit = GPOI 17-24; connect to GPOI 17-24 connector on breakout panel.
Legend on GTP-32 unit = GPOI 25-32; connect to GPOI 25-32 connector on breakout panel
Example 2:
Legend on GTP-32 unit = GPI 1-16; connect to GPI 1-16 connector on breakout panel.
Legend on GTP-32 unit = GPI 17-32; connect to GPI 17-32 connector on breakout panel
Legend on GTP-32 unit = GPO 1-16; connect to GPO 1-16 connector on breakout panel.
Legend on GTP-32 unit = GPO 17-32; connect to GPO 17-32 connector on breakout panel
B.
CONNECTING THE EXTERNAL INPUTS AND OUTPUTS
1)
PHOENIX TWO PIN CONNECTORS.
Each GPI and each GPO has its own 2 pin connector. The GPOs are on the top row and the GPIs are on
the bottom row. Each GPI and GPO may be configured for Wet or Dry mode using jumpers below the
phoenix connector. When using the WET mode, only use a switch closure across the pins.
2)
SET GPI WET/DRY MODE
Configure Wet/Dry mode for each individual GPI using the jumpers below the GPI connector. The DRY
mode uses only one jumper across the two center pins (D). The wet mode uses two jumpers across the
two outside pins (WW).
3)
SET GPO WET/DRY MODE