DMX4ALL DMX-Servo-Control 2 User Manual Download Page 12

 

DMX-Servo-Control 2

 

12 

 

Dimensions 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

All details in mm 

Summary of Contents for DMX-Servo-Control 2

Page 1: ...DMX Servo Control 2 User Manual...

Page 2: ...ontrol 2 is between 5V and 12V Servos with a supply voltage within this range can be connected directly Adjustable Servo control signal The controlling occurs via an adjustable pulse width Compact Des...

Page 3: ...RDM Servo Voltage 5 12V DC corresponds to the supply voltage Servo Power max 3A in sum for both servos DMX Channels 2 Channels Connection 1x screw terminal 2pin 1x screw terminal 3pin 2x pin header R...

Page 4: ...DMX Servo Control 2 4 Connection ATTENTION This DMX Servo Control 2 is NOT ADMITTED for applications whom has safety relevant requirements or in which dangerous situations can occur...

Page 5: ...LED shows the current status In this case the LED lights up in short pitches and then is missing for longer time The number of the flashing lights is equal to the event number Status Number Error Desc...

Page 6: ...address Address Switch Address Switch 1 ON OFF 1 2 3 4 5 6 7 8 9 10 2 ON OFF 1 2 3 4 5 6 7 8 9 10 508 ON OFF 1 2 3 4 5 6 7 8 9 10 3 ON OFF 1 2 3 4 5 6 7 8 9 10 509 ON OFF 1 2 3 4 5 6 7 8 9 10 4 ON OFF...

Page 7: ...the Servo Normally this impulse is between 1ms and 2ms which is also the standard setting for the DMX Servo Control 2 These are the end positions of the Servos where it is not limited mechanically A...

Page 8: ...the DIP Switched 1 8 the Minimum time Set DIP Switch 9 on ON Set via the DIP Switched 1 8 the Maximum time Set DIP Switch 10 on OFF The LED lights up 4x as confirmation that the settings are stored S...

Page 9: ...FF A DMX start address set by the address switches is always prior This device supports the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQUE_BRANCH E1...

Page 10: ...ET Send PDL 0 Receive PDL 21 21 Byte ASCII Text LEFT_ADJUST PID 0xD450 Sets the high time length for left servo position GET Send PDL 0 Receive PDL 2 1 Word LEFT_ADJUST_TIME SET Send PDL 2 1 Word LEFT...

Page 11: ...ect power supply Set address switch 1 to 10 on ON Turn on the device Connect power supply Now the LED flashes 20x within ca 3 seconds While the LED is flashing set switch 10 to OFF The factory reset i...

Page 12: ...DMX Servo Control 2 12 Dimensions All details in mm...

Page 13: ...the EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with ap...

Page 14: ...he board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it...

Page 15: ...ems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to poi...

Reviews: