DMX-RELAIS 2 INRUSH
7
DMX-FAIL Function
The
DMX-RELAIS 2 INRUSH
has a DMX-FAIL Function which stores the last value
in the case of a DMX signal loss (HOLD) or left the relays unchanged with a
predefined value in its conditions.
The DMX-HOLD function can be activated via RDM or by switch 10.
Switch 10 ON
DMX-HOLD active
Switch10 OFF
DMX-HOLD not active
If HOLD is switched on (switch 10 = ON), the last received DMX values are remained
in case of a DMX signal failure.
If HOLD is switched off (switch 10 = OFF), the DMX values are replaced with a value
set by RDM in case of a DMX signal failure. In the delivery state this value is 0, so
that the relays switch off.
In case of a power failure the DMX values held with HOLD are discarded!
A value set by RDM is deleted when HOLD is selected. After switching off the
HOLD function, the default value 0 is used.