background image

 

 

 
 
 
 
 
 

ArtNet Relais/Analog Interface 4 

 
 
 
 
 
 

User manual

 

 

 

 

 

 

 

 

 

Summary of Contents for ArtNet Relais/Analog Interface 4

Page 1: ...ArtNet Relais Analog Interface 4 User manual...

Page 2: ...tages from 12V up to 24V DC DMX Art Net or RDM Optionally the ArtNet Relais Analog Interface can be controlled via DMX Art Net DMX over Ethernet or RDM Remote Device Control RDM support The ArtNet Rel...

Page 3: ...browser so that no access to the device is necessary DMX4ALL Command interface The ArtNet Relais Analog Interface has another TCP communication interface This interface uses the DMX4ALL Commands via...

Page 4: ...2 ArtNetTM downwards compatible DMX4ALL Commands RDM DMX channels 4 up to 12 channels Output 4x switch contacts closer NO Each max 8A 250V 165A 20ms inrush current or up to 8A DC note max DC load 4x a...

Page 5: ...nalog Interface 4 5 Max DC load The maximum current the switch contacts of the ArtNet Relais Analog Interface can switch is shown in the following graph depending on the switching voltage Quelle Data...

Page 6: ...peration with DMX ArtNet Relais Analog Interface ADDRESS DMX OUT 1 2 3 4 POWER 12 24V DMX IN POWER POWER max 10mA ANALOG OUT Operation with ArtNet ArtNet Relais Analog Interface ADDRESS 1 2 3 4 POWER...

Page 7: ...shing signals is equal to the number of the error status Error Status Error Description 1 No DMX There is no DMX signal at the entry 2 Address error Please check the adjusted starting address DMX Addr...

Page 8: ...he program IP Configurator The ArtNet Relais Analog Interface is shown in the list Select the entry click Enter the new IP and net mask Click SET Set the IP with web browser The assigned IP Address wh...

Page 9: ...g configuration site Each ArtNet Node needs an own IP Address so the assignment in the network is clear Use in accordance to the ArtNet Specification the IP Address 2 x x x or 10 x x x The Net mask is...

Page 10: ...omplies to relay 1 and the following addresses comply to relay 2 4 followed by the analog outputs 1 4 If a DMX Starting address is adjusted via the switches this address is regarding prior Note that t...

Page 11: ...Jumper 1 this mode is activatable In this case the DMX Channel assignment is as following DMX Channel assignment by 8 Bit DMX Channel assignment by 10 Bit Analog Relais 1 Analog Relais 2 Analog Relai...

Page 12: ...ing the analog output there is needed per output one or two DMX channels as shown in the following picture DMX channel configuration with 8 Bit DMX channel configuration with 10 Bit Relais 1 Relais 2...

Page 13: ...a RDM or switch 10 Switch 10 ON DMX HOLD active Switch 10 OFF DMX HOLD not active If HOLD is switched on switch 10 ON the last received DMX values are kept in case of a DMX signal failure If HOLD is s...

Page 14: ...DMX4All Commands from the separated DMX4ALL Command description VCP Control For controlling via a COM Port a TCP VCP program must be installed providing a virtual Com Port VCP We recommend the tool Se...

Page 15: ...ArtNet Relais Analog Interface 4 15 Finally click Update all in the main menu to activate the VCP Now the status Available is shown and the COM Port is displayed in the device manager...

Page 16: ...ress switches is always prior This device supports the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQUE_BRANCH E1 20 DISC_MUTE E1 20 DISC_UN_MUTE E1 2...

Page 17: ...ais Analog Interface 4 17 Manufacturer depending RDM control commands SERIAL_NUMBER PID 0xD400 Outputs a text description ASCII Text of the device serial number GET Send PDL 0 Receive PDL 21 21 Byte A...

Page 18: ...e device Place the MODE Jumper J1 to J2 as shown Turn on the device The reset executes and the LEDs at the RJ45 connection light up 3x simultaneously as confirmation Alternatively you can generate the...

Page 19: ...from the list Click Firmware Update Select the Firmware Data bin and confirm Wait until the Update has finished Set the MODE Jumper to the original condition If during the Update occurs an error you c...

Page 20: ...ArtNet Relais Analog Interface 4 20 Dimensions all details in mm...

Page 21: ...ArtNet Relais Analog Interface 4 21 Equipment Top hat rail housing 1050 Power supply 12V...

Page 22: ...e with the EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance w...

Page 23: ...board the board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and unders...

Page 24: ...ems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to poi...

Reviews: