SIGNAL INDICATORS
Signalling is only provided on models with display fitted.
The state of the booster/splitter is signalled by a 3-digit LED display.
Indication (e.g.) Meaning
Description
- - -
empty
no data received
Err
ERROR
no DMX data reception, or non-standard signal (e.g. other RS-485 protocol)
brk
BREAK
break error (signal error)
syn
SYNC
sync error (sync timing signal error)
rdn
RDM
RDM signal packet detected
512
CHANNELS
data reception o.k., number of channels received is being displayed
TECHNICAL DATA
Dimensions
114mm (W) x 67mm (H) x 114 mm (D)
Supply:
230V AC 50 Hz approx. 4 W
DMX IN:
1 Unit Load
DMX OUT:
>10 unit load, individually buffered, individually optically isolated to input, SRL driver
Display:
3 digit, status and channel count
Order No.:
3404C-FG / 3405A-FG / 3408A-FG
DMX RDM PROPERTIES
The splitter can process DMX512, DMX512-A and/or DMX RDM telegrams. In respect
to RDM traffic, the splitter acts as "invisible" device, which cannot be discovered or ad-
dressed. Please refer to the relevant product page (see below) for more information
regarding RDM properties.
Product pages:
3404C-FG
www.soundlight.de/produkte/3404c-fg
3405A-FG
www.soundlight.de/produkte/3405a-fg
3408A-FG
www.soundlight.de/produkte/3408a-fg
CE CONFORMITY
This DMX splitter/booster is microprocessor controlled and uses high frequency
(16 MHz quartz). The interface has been tested in our EMC lab to comply with DIN
EN55015.
To ensure the best performance regarding radiated and conducted emissions please
make sure that shielded data cable is used and the shield is connected properly to the
GND pin. Shield must never make contact to other signal lines.
DISTURBANCES
If a trouble-free operation cannot be guaranteed, disconnect the booster/splitter and secure it against unwan-
ted operation. This is especially necessary, when
- the unit has visible damages;
- the unit does not operate;
- internal parts are loose;
- connection cables show visible damages.