4.Wiring
Terminal
Lable
Function
1
2
3
4
5
6
7
8
V+
V-
C
NC
NO1
NC1
C1/T2
T1
Voltage
12VDC
arming relay
Undefined
Tamper
terminal block sketch
Bottom shell
surface shell
ON
LED can be used
OFF
LED can not be used
LED can
not be used
to make sure in the course of
alarming, the LED is on, the
factory default , ON
PIR
sensitivity
2
2
Standard: reduce the fault alarming at the most extent.
Can bear extreme environment.
Middle-level
used in the status of intruder only can
enter in the too narrow protected place
Bear the normal environment status
Remark
The supplying detector set to be standard mode
On
standard
OFF
middle level
3
3
Un-used
4
4
6
6
5
5
On
sum mode
OFF
or mode
Remark
suggest not use "OR" in most of the installation,under same situations,
the "OR" mode can have a quicker testing speed. But it also will
increase the probability of fault alarm, because the detector activate
the alarming through the input of the single technology.
7.Walking test
Remark
before the walking test, please make sure the detector is fixed at the installing , all the lines are connected and the power is ON
Remark
Check LED is On
please refer to the part of DIP1
Remark
To avoid the fault alarming , set the MW dial to be the min before the walking test.
MW range
PIR range
1.After the power ON and the self-checking is over, then start the walking test. LED will flash with the red till
the detector in a stable status and in 2S there is no moving .
2.When you walk to the edge of the covering area, look at the status of LED, and the LED will be on out of the covering area.
3.Repeat the step 3 at the different direction till the suitable verifying the area edge.
Blue LED will be on, to recognize the covering area's edge of PIR
Blue LED will flash, to recognize the covering area's edge of MW
4.rRepeat the step 3 in a reverse direction
5.If still not reach the requiring rang, please turn the MW adjuster counterclockwise with a little step to
increase the value of the MW adjuster.
6.Repeat walking test and make the adjustment till achieve the most far covering area.
+
adjust the MW sensitivity
counterclockwise: weaken
clockwise: strengthen
Strengthen
Weaken
MW inspect
If the part of the MW stopped emitting or
receiving signal, the detector will be locked
up at the alarming status. If the normal
emitting or receiving , the detector will
return to the normal working status.
NOTE
To make sure the stable and
reliable working,need to
check the detector once a month
5.Adjust the MW sensitivity
AND) mode
OR
mode
two technology detect the alarming status at the same time
PIR or the MW detects the alarming status