4.Wiring 

Terminal

Lable 

Function

1
2
3
4
5
6
7
8

V+
V-
C
NC
NO1
NC1
C1/T2
T1

Voltage

12VDC

arming relay

Undefined 

Tamper 

terminal block sketch 

Bottom shell

surface shell

 ON

LED can be used

OFF

LED can not be used

LED can 

not be used             

to make sure in the course of 

alarming, the LED is on, the 

factory default ,  ON

PIR 

sensitivity              

2

2

Standard: reduce the fault alarming at the most extent.
Can bear extreme environment.
Middle-level

used in the status of intruder only can

enter in the too narrow protected place   
Bear the normal environment status
Remark

The supplying detector set to be standard mode

 On

standard 

OFF

middle level

3

3

 Un-used         

4

4

6

6

5

5

 On

sum mode

OFF

or mode

Remark

suggest not use "OR" in most of the installation,under same situations, 

                  the "OR" mode can have a quicker testing speed. But it also will 
                  increase the probability of fault alarm,  because the detector activate 
                  the alarming through the input of the single technology.

7.Walking test

Remark

before the walking test, please make sure the detector is fixed at the installing , all the lines are connected and the power is ON 

Remark

Check  LED is On

 please refer to the part  of DIP1

Remark

To avoid the fault alarming , set the MW dial to be the min before the walking test.

MW  range

PIR range

1.After the power ON and the self-checking is over, then start the walking test. LED will flash with the red till
 the detector in a stable status and in 2S there is no moving .  
2.When you walk to the edge of the covering area, look at the status of LED, and the LED will be on out of the covering area.
3.Repeat the step 3 at the different direction     till the suitable verifying the area edge.  
  Blue LED will be on, to recognize the covering area's edge of PIR
  Blue LED will flash, to recognize the covering area's edge of MW
4.rRepeat the step 3 in a reverse direction
5.If still not reach the requiring rang, please turn the MW adjuster counterclockwise with a little step to 
increase the value of the MW adjuster.   
6.Repeat walking test and make the adjustment  till achieve the most far covering area.

+

adjust the MW sensitivity 
                           counterclockwise: weaken
                           clockwise: strengthen  

Strengthen 

Weaken 

 MW inspect

If the part of the MW stopped emitting or 
receiving signal, the detector will be locked
up at the alarming status. If the normal 
emitting or receiving , the detector will 
return to the normal working status.

NOTE

To make sure the stable and 

                reliable working,need to 
                check the detector once a month

5.Adjust the MW sensitivity

AND) mode

OR

mode

two technology detect the alarming status at the same time

PIR or the MW detects the alarming status