7300 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
5
Wire the Keypad
The 7360 and 7363 keypads are supplied with a 4-wire harness for panel keypad bus
connection. Refer to the following table for wire colors and connections:
WIRE COLOR
CONNECT TO PANEL
PURPOSE
Red
Terminal 7
DC Power
Yellow
Terminal 8
Send Data
Green
Terminal 9
Receive Data
Black
Terminal 10
Ground
When Using an Auxiliary Power Supply
If the current draw for all keypads exceeds the panel output, provide additional
current by adding a Model 505-12 auxiliary power supply:
1. Connect all keypad Black ground wires to the power supply negative terminal.
2. Run a jumper wire from the power supply negative terminal to the panel
common ground terminal.
3. Connect all keypad power (+12 VDC) wires to the power supply positive
terminal.
4. Do not connect the power supply positive terminal to any panel terminal.
For more information, refer to the
505-12 Power Supply Installation Guide (LT-0453)
2
Summary of Contents for Thinline 7300 Series