DMP Electronics SCS-105 Installation Manual Download Page 3

ADDITIONAL INFORMATION

Reset Button

During normal operation, the green status (ST) LED flashes about once every second. If the status LED either comes 

on steady or goes out completely the SCS-105 needs to be reset. Follow the steps below to reset the SCS-105 

receiver:

1.  Place the head of a small slotted screwdriver against the reset button.
2.  Lightly press the reset button and hold for about two seconds before releasing.
3.  Wait about five seconds for the SCS-105 initialization routine to end.

Baud Rate Setting

When using the SCS-105 with Remote Link or System Link, the Baud Rate in the software must be set to 

9600

 baud. 

You can set the Baud rate in Remote Link and System Link.

1.  Select 

System > Configure > Remote Link

 (or System Link) 

> Receiver

 tab. 

2.  In the Baud Rate field, select 

9600

 from the drop-down menu.

Receiver Key Programming

The SCS-105 comes with a blank default receiver key. This allows you to perform remote operations as the service 

receiver. Make the default key unique to this SCS-105 to restrict unauthorized remote programming. 
Note: For additional information, see the Remote Link User’s Guide (LT-0565) or System Link User’s Guide (LT-0570).

Answering Machine Bypass Function

If you are contacting a panel that has answering machine bypass capability, the SCS-105 turns on a carrier tone five 

seconds after it finishes dialing the account phone number. The carrier tone is on for approximately 90 seconds while 

the subscriber’s panel will pick up the phone line and communicate with the Remote Link or System Link computer. 

Note:

 This requires SCS-105 firmware version 207 or higher.

Volume Control

You can adjust the volume control to listen to data transmissions between the SCS-105 and DMP panels. 

•  Set the volume control at about one sixth of a turn clockwise for normal listening levels, 
•  Turn the volume controler fully counterclockwise to mute the SCS-105.

Adding a Telephone

You can connect a standard telephone to the rear 

TELEPHONE

 port of the SCS-105 to call and talk to a subscriber at 

the premises prior to any remote operations.

Digital Dialer Mode

The SCS-105 receiver comes configured for 2-wire digital dialer operation and no hardware adjustments are necessary.