This option allows you to program communicator output options. Switched ground (open
collector) outputs are available using terminals O1 and O2 as the ground and your control
panel for power. Select from outputs 1 or 2.
CUTOFF OUTPUTS
Define the operation of the two on‑board outputs. For each programming option, enter
the output you wish to activate or 0 for no output. Either or both of the outputs can be
programmed here to turn off after the time specified in output cutoff time. To disable this
option, press any select area to clear the display of output numbers and then press CMD.
OUTPUT CUTOFF TIME
If a cutoff output is assigned, you can enter a cutoff time for the output to remain on up to
15 minutes. If the output is turned off manually, the cut off time is reset. The cutoff time can
be 1‑15 minutes. Enter 0 to provide continuous output.
Note
: The output is cutoff within 60 seconds of the programmed cutoff time.
The cutoff timer is shared by all outputs. If a second output trips, the timer is not reset.
Both outputs turn off when the original time expires.
COMMUNICATION FAILURE OUTPUT
This output/favorite turns on when the communicator fails to communicate with the
receiver. To turn off communication failure output, disarm the communicator. Enter 0 to
disable this output.
ARMED OUTPUT
This output/favorite turns on any time an area of the system is armed. The output turns off
when the system completely disarms. Enter 0 to disable this output.
REMOTE ARMING OUTPUT
When the system is armed or disarmed remotely from the Virtual Keypad app,
VirtualKeypad.com, Remote Link, or from a schedule, this output turns on momentary for
.75 seconds then turns off. This output can be used for panels that require a momentary
short to an arming zone to arm and a momentary short to disarm.
HEAT SAVER TEMPERATURE (ICOMSLZ ONLY)
Enter the desired temperature setting for all Z‑Wave thermostats when the system is
armed ALL. When the system is disarmed, the thermostats return to their previous settings.
The range is 55‑95 degrees. Enter 0 to disable.
COOL SAVER TEMPERATURE (ICOMSLZ ONLY)
Enter the desired temperature setting for all Z‑Wave thermostats when the system is
armed ALL. When the system is disarmed, the thermostats return to their previous settings.
The range is 55‑95 degrees. Enter 0 to disable.
OUTPUT OPTIONS
CO OUTS: ‑ ‑
CUTOFF TIME:
0
COMM FAIL OUT: 0
ARMED OUT:
0
RMT ARMG OUT: 0
HEAT SAVER
TEMPERATURE: 0
COOL SAVER
TEMPERATURE: 0