734 Installation and Programming Guide | Digital Monitoring Products
10
734 Address Table
To set the module’s address, move the DIP switches to the appropriate positions. See Figure 11 for Keypad Bus
and AX-Bus DIP switch positions.
KEYPAD BUS
AX-BUS
Device/
Door
Zones
Device/
Door
Zones
Device/
Door
Zones
Device/
Door
Zones
Device/
Door
Zones
Device/
Door
Zones
1
11-14
501
501-504
601
601-604
701
701-704
801
801-804
901
901-904
2
21-24
505
505-508
605
605-608
705
705-708
805
805-808
905
905-908
3
31-34
509
509-512
609
609-612
709
709-712
809
809-812
909
909-912
4
41-44
513
513-516
613
613-616
713
713-716
813
813-816
913
913-916
5
51-54
517
517-520
617
617-620
717
717-720
817
817-820
917
917-920
6
61-64
521
521-524
621
621-624
721
721-724
821
821-824
921
921-924
7
71-74
525
525-528
625
625-628
725
725-728
825
825-828
925
925-928
8
81-84
529
529-532
629
629-632
729
729-732
829
829-832
929
929-932
9
91-94
533
533-536
633
633-636
733
733-736
833
833-836
933
933-936
10
101-104
537
537-540
637
637-640
737
737-740
837
837-840
937
937-940
11
111-114
541
541-544
641
641-644
741
741-744
841
841-844
941
941-944
12
121-124
545
545-548
645
645-648
745
745-748
845
845-848
945
945-948
13
131-134
549
549-552
649
649-652
749
749-752
849
849-852
949
949-952
14
141-144
553
553-556
653
653-656
753
753-756
853
853-856
953
953-956
15
151-154
557
557-560
657
657-660
757
757-760
857
857-860
957
957-960
16
161-164
561
561-564
661
661-664
761
761-764
861
861-864
961
961-964
Table 2: Device Addresses and 734 Zone Numbers
9
Connect the Power Supply
Power for the 734 can be provided by a 12 or 24 VDC power supply. The 12 VDC power can be provided by the
panel keypad bus or from a separate power supply. The 24 VDC power supply can be connected directly to the
relay terminal block (J1).
Warning:
To avoid the risk of equipment damage, do not exceed 750 mA total output current for zones
connected to the module.