711S ZONE EXPANSION MODULE
Installation Guide
DESCRIPTION
Figure 1: 711S Zone Expansion Module
The 711S is a flying lead style,
single-zone, addressable expansion
module that allows you to increase
the number of reporting zones
available on DMP panels. Refer to
the panel installation guide for more
information about zone expansion
modules and the maximum number
allowed per panel. The modules
connect to the panel 4-wire Keypad
Bus or LX-Bus™ and are set to
an address that determines the
reporting zone number. The 711S
provides one Type A Class B zone.
Compatibility
All XT30/XT50 and XR150/XR550
Series Panels.
What is Included?
•
711S Expansion Module
•
1k Ohm Resistor
1
ADDRESSING THE 711S MODULE
The 711S addressable zone expansion module is for use in smaller
applications, such as installing in a pull station back-box or even in a
recessed contact hole behind the contact.
LX-Bus Zone Numbers
Refer to Table 2 for a partial list of XR550 Series panel LX-Bus zone
numbers. XR150 Series panels only use LX500. For LX-Bus addresses set
the switches to match the last two digits of the address.
Setting Address Switches
The 711S Zone Expander uses two rotary switches identified as TENS and
ONES to set the module address. Use a small
screwdriver to set the address accordingly for
Keypad Bus (See Table 1) or LX-bus (See Table 2).
For example, for address
502
on an XR550 Series
panel set the
TENS
switch to zero and the
ONES
switch to two as shown in Figure 2.
LX-Bus
Address
LX-Bus
Number
Switches
Tens
Ones
Zone
Number
501
1(LX500)
0
1
501
506
1(LX500)
0
6
506
623
2(LX600)
2
3
623
654
2(LX600)
5
4
654
742
3(LX700)
4
2
742
768
3(LX700)
6
8
768
833
4(LX800)
3
3
833
877
4(LX800)
7
7
877
919
5(LX900)
1
9
919
994
5(LX900)
9
4
994
Table 2: Example LX-Bus Zone Numbers
Keypad Bus Zone
Numbers
The 711S module uses the first
zone number only. The last three
zone numbers cannot be used
for other devices. For example,
turn the 711S switches to address
02 (
TENS
= 0,
ONES
= 2) to set
the module zone number to zone
21. Zones 22, 23, and 24 cannot
be used.
Refer to Table 1 for Keypad Bus
zone numbers and the panels
where they operate.
Keypad
Address
Switches
Tens Ones
Zone Number
XT30/50 XR150
XR550
1
0
1
11
11
11
2
0
2
21
21
21
3
0
3
31
31
31
4
0
4
41
41
41
5
0
5
51
51
51
6
0
6
61
61
61
7
0
7
71
71
71
8
0
8
81
81
81
9
0
9
N/A
N/A
91
10
1
0
N/A
N/A
101
11
1
1
N/A
N/A
111
12
1
2
N/A
N/A
121
13
1
3
N/A
N/A
131
14
1
4
N/A
N/A
141
15
1
5
N/A
N/A
151
16
1
6
N/A
N/A
161
Table 1: Keypad Bus Zone Numbers
INSTALLING THE 711S MODULE
Wiring the 711S Module
Connect the
Red
,
Yellow, Green
, and
Black
wires from the panel Keypad
Bus or LX-Bus™ to the matching wires on the zone expander.
Caution: Do not use looped wire under terminals if wiring directly
to the Keypad bus. Break wire run to provide supervision of
connections.
2
0
1
2 3 4
5
6
7
8
9
0
1
2 3 4
5
6
7
8
9
TENS ONES
Figure 2: Switches