Specifications

Dimensions    6.8" W x 5.25" H x 5" D
Ordering Information: 699 

    Plexiglass

   

   

  699-W     Metal

Compatibility

The 699 Keypad Deskstand is compatible with all 

DMP LCD Keypad models.

Accessories

778 Keypad Backplate

 

Dimensions 

6.57" W x 4.57" H

Wiring Specifications

When planning a keypad bus installation, keep in mind the following specifications:

1. DMP recommends using 18 or 22-gauge 

unshielded 

wire for all keypad and LX-Bus circuits. 

Do Not

 use 

twisted pair or shielded wire for LX-Bus and keypad bus data circuits. To maintain auxiliary power integrity 

when using 22-gauge wire do not exceed 500 feet. When using 18-gauge wire do not exceed 1,000 feet. 

Install an additional power supply to increase the wire length or add devices.

2. Maximum distance for any one circuit (length of wire) is 2,500 feet regardless of the wire gauge. This 

distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 

2,500 feet. As wire distance from the panel increases, DC voltage on the wire decreases.

3. Maximum number of devices per 2,500 feet circuit is 40.

 

Note:

 Each panel allows a specific number of supervised keypads. Add additional keypads in the unsupervised 

mode. Refer to the panel installation guide for the specific number of supervised keypads allowed.

4. Maximum voltage drop between the panel (or auxiliary power supply) and any device is 2.0 VDC. If the 

voltage at any device is less than the required level, add an auxiliary power supply at the end of the circuit. 

When voltage is too low, the devices cannot operate properly.

Refer to the LX-Bus/Keypad Bus Wiring Application Note (LT-2031). Also see the 710 Module Installation Sheet 

(LT-0310) for more information.

Summary of Contents for 699

Page 1: ...1 as needed 1 Refer to the keypad installation guide and remove the cover from the keypad base 2 Align the keypad base to the four keypad mounting holes on the 699 Deskstand 3 Insert the screws through the keypad base and 699 Deskstand 4 Use a Phillips head screwdriver to tighten the four screws into place Do not overtighten 5 Replace the keypad cover Wire Harness wire tie strain relief mounting h...

Page 2: ... Premounted feet 4 places Clear Touch Keypad wiring harness opening 778 Backplate 778 Backplate side view Deskstand and 778 Backplate Front View Deskstand and 778 Backplate Side View Clear Touch Keypad mounting hole Flush mounting holes Wire Harness wire tie strain relief mounting holes located in Deskstand base Figure 2 699 Keypad Deskstand with 778 Backplate Installed Wiring Panel to Wiring Bloc...

Page 3: ... 5 shows the 699 Backplate rear view with the 4 wire connector plugged into the 4 pin header Run a tie wrap through the back or base of the 699 Deskstand Roll the excess length of the 4 ft Wire Harness into a loop and use the tie wrap to hold it in place Wire Harness with wire tie strain relief in place 4 wire connector plugged into keypad 4 pin header Deskstand Rear View RED To Wiring Block Optio...

Page 4: ... not exceed 1 000 feet Install an additional power supply to increase the wire length or add devices 2 Maximum distance for any one circuit length of wire is 2 500 feet regardless of the wire gauge This distance can be in the form of one long wire run or multiple branches with all wiring totaling no more than 2 500 feet As wire distance from the panel increases DC voltage on the wire decreases 3 M...

Reviews: