DMP Electronics 1144 Series Installation Manual Download Page 2

 2 

1144 INSTALLATION GUIDE     |     DIGITAL MONITORING PRODUCTS 

1

PROGRAM THE PANEL

Remove the Battery Isolation Tab

To activate the battery, remove the battery isolation pull tab. When 

removed, the key fob will be active and may be programmed into the 

system. See Figure 3.

Program the Key Fob

After completing each of the following steps, press 

CMD

 to advance to the next option. Refer to the appropriate 

panel programming guide as needed. 

1.  At a keypad, enter 

6653

 (PROG) to access the Programmer Menu.

2.  (1144E Series only) Go to 

SYSTEM OPTIONS

. At 

1100 ENCRYPTION

, select 

ALL

 to only add encrypted wireless 

devices to the system. Select 

BOTH

 to allow both encrypted 

and non‑encrypted wireless devices to be programmed.

3.  (1144E Series only) The default passphrase is displayed at the 

ENTER PASSPHRASE

 prompt. Press 

CMD

 to keep the default. 

Press any select key or area to change the passphrase and 

enter an 8‑character hexadecimal string (0‑9, A‑F).

4.  (XR Series panels only) To enable panic supervision for the 

1144‑1P‑PSV, go to 

SYSTEM OPTIONS

. At 

PANIC SUPERVISION

select 

YES

.

5.  Go to 

ZONE INFORMATION

 and enter the wireless zone number. Refer to Table 2 for zone numbers. 

6.  (XT Series panels only) At 

KEYFOB 

select

 YES

.

7.  At 

KEY FOB USER NUMBER

, enter an existing user number to be associated with the key fob. If the user 

does not exist, the keypad displays 

USER X NOT IN USE

. The key fob can be programmed, but the user 

must be created for it to function properly.

8.  At 

TRANSMITTER SERIAL#

, enter the eight‑digit key fob serial number.

9.  At 

TRANSMITTER SUPRVSN TIME

, select a supervision time for the key fob. The default is 

0

 minutes. For 

applications where the key fob may be taken off‑site, supervision time should be set to 

0

 (zero).

Program Key Fob Buttons

Refer to Table 3 when programming button actions.

1.  At 

NO. OF KEY FOB BUTTONS

enter the number of buttons on 

the key fob (1, 2, or 4).

2.  At 

BUTTON

, select the button 

that you want to program: 

TOP

BTM

LFT

, or 

RGT

.

3.  At 

BUTTON ACTION

, choose an 

action for the button.

4.  Configure press time or output 

options as needed.

5.  Repeat the steps in this section 

as needed for each key fob 

button.

6.  At the 

NEXT ZONE

 prompt, 

select 

YES

 if you are finished 

programming the zone. Select 

NO

 if you would like to access 

additional programming options.

7.  To save panel programming, go 

to 

STOP

 and press 

CMD

.

Program the 1144-1P and 1144-2P Credential

Present the credential to a keypad or card reader to program the user credential. For information about adding 

user codes, refer to the panel user guide.

PULL

Remove Battery

Isolation Tab to 

Activate Battery

Figure 3: Battery Isolation Tab

PANEL MODEL

ZONE NUMBERS

XR150/XR550 Series

400‑449

XT30/XT50 Series

31‑34 (slow)

41‑44 (fast)

XTLplus and XTLtouch

51‑54 (slow)

61‑64 (fast)

Table 2: Key Fob Zone Numbers

ACTION

SELECT

OPTIONS

Arm

ARM

Short/Long Press, Arm/Disarm Areas

Disarm

DIS

Short/Long Press, Arm/Disarm Areas

Toggle

TGL

Short/Long Press, Arm/Disarm Areas

Status LED

STA

Short/Long Press

Panic

PN

Output Number, Output Action

Panic (2‑button)

PN2

Output Number, Output Action

Emergency

EM

Output Number, Output Action

Emergency (2‑button)

EM2

Output Number, Output Action

Output

OUT

Output Number, Output Action

Sensor Reset

RST

Short/Long Press

Unused

UN

Table 3: Key Fob Button Programming Information