background image

 

DER-S0081A 

11 

Rev. 4.0 ©2005 - 2011 DMC Co., Ltd. 

FST Series Product Specifications

7. Revision history 

 
 

Rev1.0 (May 11, 2005) 

 Initial 

release 

 
 

Rev1.1 (July 13, 2005) 

 

4-1.Recommended Connector is changed RE-H052SD-1130 to RE-H052SD-1110. 

 

6-1.Warranty Period is changed 5 years to 3 years. 

 
 

Rev2.0 (October 13, 2006) 

 

The specification item name was changed. 

 

 

1-3.”Storing Temperature” to “Storage Temperature” 

 

 

1-3.”Storing Humidity” to “Storage Humidity” 

  

1-4.”Operating 

Load” 

to “Activation Force” 

 

 

1-4.”Light Transmissivity” to “Light Transmittance” 

 

 

1-4.”Top Surface Hardness” to “Surface Hardness” 

  

2-3.”Operating 

Load 

Test” 

to “Activation Force Test” 

  

2-3.”Operating 

Load” 

to “Activation Force” 

  

3-1.”Operationg 

Load” 

to “Activation Force” 

 

1-4.Activation Force is changed “0.5N

±

0.3” to “0.05N to 0.8N”. 

 

1-5.Linearity: Added “5% inside of active area after 9 points calibration.” 

 

1-5.Insulation Resistance is changed 100M

Ω 

to

 

20M

Ω. 

 

1-6.The appearance inspection standard was improved. 

 1-6.Tip, 

crack: 

Deleted

 “Applied only in the Active Area. Scratches or dusts in the outside of the Active Area are 

acceptable unless the electrical characteristics are affected.”

 

 

2-4.Added “Operating Life Test (Pen)”. 

 
 

Rev3.0 (March 23, 2010) 

 

1-6. Appearance specification was revised. Characters of scratch/dust were classified into Circular and 

Linear. The total acceptable number of scratch/dust was added.   

 

2-3. Unit of Load (g) changed to (N) to unify the unit 

 

2-3. Operating Life Test (Finger)  Activation Force, Within 

±

50% of the specification 

 Must satisfy 

the specification. (Clerical error was corrected)   

 

2-3. Operating Life Test (Pen)    Activation Force, Within 

±

50% of the specification 

 Must satisfy the 

specification. (Clerical error was corrected)   

 

3-1. Temperature Condition   Cold Test  -30

 -40

  (Clerical error was corrected) 

 3-1. 

Activation 

Force, 

Within 

±

50% of the specification. 

 Must satisfy the specification   

(Clerical error was corrected) 

 
Rev4.0 (Aug 25, 2011) 

    6-4. Tools: The below description has been deleted.   

“To maintain the quality, the printing screens and the die-cut plates are generally limited to 
use up to 1 year. Reorders after 1 year from the initial order or from the last renewal are 
subject to the tooling charge for replacing the printing screens and the die-cut plates. 
Reorders for the discontinued standard parts are also subject to tooling charge.” 

 

Summary of Contents for 5 Wire Analog Resistive Touchscreen FST Series

Page 1: ...5 Wire Analog Resistive Touchscreen FST Series Product Specifications...

Page 2: ...5 2 2 Environmental Specifications 5 2 3 Mechanical Characteristics 5 2 4 Electrical Characteristics 5 2 5 Appearance 6 3 Reliability Condition 7 3 1 Temperature Condition 7 4 Recommended Connector 7...

Page 3: ...g m3 no condensation Chemical Resistance top surface Toluene Tricholoroethylene Athetone Alcohol Gasoline Machine Oil Ammonia Glass Cleaner Mayonnaise Ketchup Wine Salad Oil Vinegar Lipstick etc 1 4 M...

Page 4: ...eptable 0 4 D 0 3 1 1pcs in viewing area 1 0 3 D 0 2 2pcs in 30mm Circular Scratch Dust 0 2 D Acceptable Within 5pcs panel Applied only in the Active Area Scratches or dusts in the outside of the Acti...

Page 5: ...od Judgement Must satisfy the specification Operating Life Test Finger Condition Testing rod Refer to Figure 1 Voltage DC5V Load 3N Cycle 2 hits sec Judgement Must satisfy the following Activation For...

Page 6: ...nce Test Neighboring Terminals Measured by applying the reference voltage to the terminals Active Area Electrodes Measured by applying the reference voltage to the top and bottom electrodes Judgement...

Page 7: ...idity 90 to 95 for 240 hours and in the room temperature for 2 hours Cycle Test Tested after 5 cycles of leaving the parts in the temperature 30 C 3 C for 1 hour and in the room temperature for 0 5 ho...

Page 8: ...ohol When contaminated by chemicals wipe them off immediately with caution not to cause injury to human body The edge of the glass is not rounded and may cause injury 5 3 Construction Notes The enviro...

Page 9: ...t not be forcibly stressed or bent too hard to avoid the conduction in the insulated area and wire breaking Mounting Touchscreen must be held from the bottom such as the structure gluing the touchscre...

Page 10: ...fer by the user Any malfunctions and damages caused by a natural disaster or a fire Any malfunctions and damages caused by static electricity Any malfunctions and damages caused by the failure of the...

Page 11: ...rea are acceptable unless the electrical characteristics are affected 2 4 Added Operating Life Test Pen Rev3 0 March 23 2010 1 6 Appearance specification was revised Characters of scratch dust were cl...

Page 12: ...DER S0081A 12 Rev 4 0 2005 2011 DMC Co Ltd FST Series Product Specifications 6 6 RoHS Compliance Description about RoHS compliance has been added...

Page 13: ...ons Rev 4 0 August 25 2011 2005 2010 DMC Co Ltd This document can be freely distributed but any alternation to this document is prohibited http www dmccoltd com english 9th floor Kanda Sento Building...

Reviews:

Related manuals for 5 Wire Analog Resistive Touchscreen FST Series