This brief instruction of mounting the FlexxPump 125 B
addresses to experienced users. Please visit
www.dls-schmiersysteme.de to download the complete user
manual including all safety instructions.
1. Overview FlexxPump 125 B
2. Technical data
3. Mounting
4. Commissioning
5. Operation and settings
1. Mechanical fastening
Fix the FlexxPump 125 B mechanically through the M5 female
threads or through the G1/4 male thread of the lubricant outlet. Pay
particular attention to the maximum tightening torques permissible
for the M5 female threads!
2. Power on
3. Execute FIL function
4. Hydraulic connection
Connect the consumer hydraulically to the FlexxPump 125 B. If you
connect tubes to the FlexxPump 125 B, make sure that tubes and
connectors are installed tightly, cleanly and correctly.
Ideally, use tubes prefilled with the appropriate lubricant.
5. Check settings on the FlexxPump 125 B
Check the required values for the lubrication point at the factory
settings of the FlexxPump 125 B and adjust them if necessary.
Factory settings: operating mode=hour mode.
No.
Description
0
FlexxPump 125 B
1 LCD
2
Operation pad (for actions with the activation
and programming key)
3
Activation and programming key
4
Lubricant outlet
5
M5 female thread for bottom mounting
6
Battery compartment
7
Serial number
8
M5 female thread for rear mounting
9
Cartridge sensor
10
Lubricant inlet with thread for cartridge
11
Nameplate with designation and CE mark
Housing
mounting options
backside: female thread M5 (2x)
bottom: female thread M5 (1x)
bottom: male thread G1/4 (1x)
max. torque mounting
3
Nm
mounting position
upright
operating temperature
Alkaline battery: + 15 ... + 60 °C
Lubricant and hydraulic
max. pressure
35 (-10 % / +15 %)
bar
grease delivery per stroke 0,15
cm³
Electrics
operating voltage
4,5
V
protection class
IP 54
1. Remove the yellow protective cap from the top of the lubricant
inlet of the FlexxPump 125 B.
2. Unscrew the yellow protective cap counterclockwise from the
bottom of the lubricant outlet of the FlexxPump 125 B.
3. Connect the battery to the battery cable using the plug.
4. Turn the cap on the lubricant cartridge counterclockwise and
pull it off.
5. Place the full lubricant cartridge with the label up front on the
FlexxPump 125 B. Turn
the lubricant cartridge
twice
clockwise
onto the FlexxPump 125 B.
Two operating modes can be selected.
The
hour mode -h-
allows setting the number of cycles (c) within
a break time (h) in hours. The cycles are evenly distributed over the
break time. Break times between 1...99 hour(s) and cycles (c) bet-
ween 1...10 can be set.
The
empty time mode Et
allows the emptying time of the cartridge
to be set in months. Emptying times between 1...24 month(s) can be
set.
5.1 Default settings operating mode hour mode -h-
Break time h = 6
The break time is 6 hours.
Number of cycles c = 1
The number of cycles is one (1) stroke
during the break time.
5.2 Menu and LCD messages
The graphic above illustrates the unchangeable basic flowchart of
the the FlexxPump 125 B menu navigation as well as the options for
branching to submenus.
the FlexxPump 125 B can be switched on and off at several points
in the menu navigation.
The INF menu provides you with an informative overview of the
current the FlexxPump 125 B settings.
The SET menu allows you to make changes to the operating
mode.
The RUN menu allows you to manually trigger a single dispense
at the FlexxPump 125 B.
The PRO menu allows you to make changes to the the FlexxPump
125 B settings - and thus to its dispensing behavior.
The FIL menu allows you to manually trigger a fixed number of
dispenses at the FlexxPump 125 B.
Display in LCD
Description
Errors
E1
Error E1 (cartridge empty / cartridge error)
E2
Error E2 (overload / overpressure)
E3
Error E3 (battery empty)
E4
Error E4 (fatal error)