It is recommended to place the pump in spaces where there is a proper ventilation and the pump is not directly exposed to heat sources.
Place the pump so as to prevent too long idraulic pipings, which would reduce its performance.
Do not position the pump above the water level (Pic. C) because it is not self-priming and the risk of the pump to run dry.
The risk of invisible air bubbles creating a vacuum area is very high. Damages which are caused by the pump running dry are excluded from warranty.
To maximize the pump’s efficiency, choose a straight inlet tube without elbows (Pic. D).
We suggest an Inlet and outlet tubes with diameter equal or bigger than the diameter of the threaded pipe included (Pic. E).
Do not use the pump leaving the outlet totally closed. A minimum water flow is necessary to keep the inner motor cool without running dry (Pic. F).
IN LINE APPLICATIONS